Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,204
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0510 # 06 Y:2006 | 06 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,135 | $640 | Implemented |
WI0510 # 07 Y:2006 | 07 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $443 | $438 | Not Implemented |
WI0510 # 08 Y:2006 | 08 | 2006 | INSTALL SET-BACK TIMERS | $340 | $100 | Implemented |
GT0817 # 01 Y:2006 | 01 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,981 | $1,333 | Implemented |
GT0817 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,933 | $164,201 | Not Implemented |
GT0817 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,177 | $9,625 | Not Implemented |
GT0817 # 04 Y:2006 | 04 | 2006 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,469 | $7,920 | Not Implemented |
GT0817 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,652 | $500 | Implemented |
GT0817 # 06 Y:2006 | 06 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $2,666 | $1,500 | Implemented |
GT0817 # 07 Y:2006 | 07 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $32,042 | $15,000 | Not Implemented |
GT0817 # 08 Y:2006 | 08 | 2006 | COMBINE UTILITY METERS | $1,987 | $0 | Not Implemented |
UD0735 # 01 Y:2006 | 01 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $212,325 | $9,000 | Implemented |
UD0735 # 02 Y:2006 | 02 | 2006 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $36,368 | $5,000 | Not Implemented |
UD0735 # 03 Y:2006 | 03 | 2006 | RECOVER MECHANICAL ENERGY | $33,450 | $32 | Implemented |
UD0735 # 04 Y:2006 | 04 | 2006 | REDUCE VENTILATION AIR | $38,385 | $0 | Not Implemented |
UD0735 # 05 Y:2006 | 05 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $14,908 | $5,056 | Not Implemented |
UD0735 # 06 Y:2006 | 06 | 2006 | DISCONNECT BALLASTS | $9,527 | $1,440 | Implemented |
UD0735 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $5,203 | $21,789 | Implemented |
UD0735 # 08 Y:2006 | 08 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,043 | $9,000 | Not Implemented |
UD0735 # 09 Y:2006 | 09 | 2006 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $3,767 | $700 | Not Implemented |
UD0735 # 10 Y:2006 | 10 | 2006 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,932 | $0 | Not Implemented |
UD0735 # 11 Y:2006 | 11 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,665 | $0 | Implemented |
UD0735 # 12 Y:2006 | 12 | 2006 | RECOVER AND REUSE COOLING WATER | $2,635 | $1,000 | Not Implemented |
UD0735 # 13 Y:2006 | 13 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,293 | $0 | Not Implemented |
UD0735 # 14 Y:2006 | 14 | 2006 | USE PHOTOCELL CONTROLS | $733 | $308 | Implemented |