Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,105

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0266 # 07 Y:2003 07 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,479 $6,285 Not Implemented
WV0266 # 08 Y:2003 08 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,937 $79 Implemented
WV0266 # 09 Y:2003 09 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,520 $150 Implemented
WV0266 # 10 Y:2003 10 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,326 $0 Implemented
WV0266 # 11 Y:2003 11 2003 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $142,002 $980,000 Not Implemented
WV0266 # 12 Y:2003 12 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,000 $2,550 Implemented
WV0266 # 13 Y:2003 13 2003 INSTALL SPECTRAL REFLECTORS / DELAMP $994 $1,240 Not Implemented
WV0266 # 14 Y:2003 14 2003 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $39,573 $0 Implemented
WV0266 # 15 Y:2003 15 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,178 $80 Not Implemented
SF0258 # 01 Y:2003 01 2003 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $10,511 $0 Implemented
SF0258 # 02 Y:2003 02 2003 UPGRADE CONTROLS ON COMPRESSORS $2,432 $580 Not Implemented
SF0258 # 03 Y:2003 03 2003 RECOVER WASTE HEAT FROM EQUIPMENT $121,871 $70,000 Not Implemented
SF0258 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $4,255 $3,120 Not Implemented
SF0258 # 05 Y:2003 05 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,169 $4,761 Implemented
SF0258 # 06 Y:2003 06 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $82,069 $76,562 Not Implemented
SF0258 # 07 Y:2003 07 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $29,851 $48,000 Not Implemented
SF0258 # 08 Y:2003 08 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $12,213 $27,140 Not Implemented
SF0258 # 09 Y:2003 09 2003 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $5,950 $25,615 Not Implemented
SF0258 # 10 Y:2003 10 2003 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $84,513 $145,200 Not Implemented
SU0161 # 01 Y:2003 01 2003 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $12,003 $16,100 Implemented
SU0161 # 02 Y:2003 02 2003 ADJUST BURNERS FOR EFFICIENT OPERATION $1,035 $540 Implemented
SU0161 # 03 Y:2003 03 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $580 $2,033 Not Implemented
SU0161 # 04 Y:2003 04 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $531 $1,608 Not Implemented
SU0161 # 05 Y:2003 05 2003 RECOVER WASTE HEAT FROM EQUIPMENT $468 $748 Not Implemented
SU0161 # 06 Y:2003 06 2003 USE SYNTHETIC LUBRICANT $272 $800 Not Implemented