Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,644
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0191 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $719 | $750 | Not Implemented |
LE0189 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,147 | $0 | Not Implemented |
LE0189 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,542 | $600 | Implemented |
LE0189 # 03 Y:2004 | 03 | 2004 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $4,151 | $6,000 | Not Implemented |
LE0189 # 04 Y:2004 | 04 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,301 | $575 | Not Implemented |
LE0189 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $293 | $0 | Implemented |
LE0189 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $145 | $0 | Not Implemented |
LE0189 # 07 Y:2004 | 07 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,806 | $1,193 | Not Implemented |
LE0190 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $65,403 | $20,000 | Implemented |
LE0190 # 02 Y:2004 | 02 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $17,844 | $50,000 | Not Implemented |
LE0190 # 03 Y:2004 | 03 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,450 | $2,500 | Not Implemented |
LE0190 # 04 Y:2004 | 04 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,412 | $750 | Not Implemented |
LE0190 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,074 | $218 | Implemented |
LE0190 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,187 | $33,512 | Implemented |
SU0187 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,725 | $0 | Not Implemented |
SU0187 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,502 | $350 | Implemented |
SU0187 # 03 Y:2004 | 03 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $513 | $442 | Not Implemented |
SU0187 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $26,177 | $53,000 | Not Implemented |
SU0187 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,721 | $10,129 | Implemented |
SU0187 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $1,206 | $3,817 | Not Implemented |
LE0185 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,836 | $43,080 | Not Implemented |
LE0185 # 02 Y:2004 | 02 | 2004 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $8,144 | $35,305 | Not Implemented |
LE0185 # 03 Y:2004 | 03 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,386 | $6,346 | Not Implemented |
LE0185 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,153 | $9,850 | Not Implemented |
LE0185 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,720 | $6,500 | Not Implemented |