IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,715

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0932 # 06 Y:2016 06 2016 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $52 $175 Not Implemented
OK0932 # 07 Y:2016 07 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $240 $125 Not Implemented
OK0932 # 08 Y:2016 08 2016 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,679 $12,315 Not Implemented
OK0932 # 09 Y:2016 09 2016 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $429 $0 Not Implemented
OK0932 # 10 Y:2016 10 2016 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,093 $30,000 Not Implemented
OK0932 # 11 Y:2016 11 2016 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $3,216 $871 Not Implemented
OK0932 # 12 Y:2016 12 2016 OPERATE BOILERS ON HIGH FIRE SETTING $16,492 $0 Implemented
OK0932 # 13 Y:2016 13 2016 REPAIR AND ELIMINATE STEAM LEAKS $4,272 $1,100 Implemented
OK0932 # 14 Y:2016 14 2016 SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE $4,116 $0 Not Implemented
AM0698 # 01 Y:2016 01 2016 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $54,900 $270,000 Not Implemented
AM0698 # 02 Y:2016 02 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,580 $11 Not Implemented
AM0698 # 03 Y:2016 03 2016 INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION $4,142 $63 Not Implemented
AM0698 # 04 Y:2016 04 2016 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,700 $0 Not Implemented
AM0698 # 05 Y:2016 05 2016 USE SYNTHETIC LUBRICANT $1,110 $0 Not Implemented
AM0698 # 06 Y:2016 06 2016 REPAIR OR REPLACE STEAM TRAPS $647 $520 Not Implemented
AM0698 # 07 Y:2016 07 2016 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $630 $1,450 Not Implemented
AM0698 # 08 Y:2016 08 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $400 $560 Not Implemented
AM0698 # 09 Y:2016 09 2016 INSTALL OCCUPANCY SENSORS $360 $460 Not Implemented
BD0475 # 01 Y:2016 01 2016 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $10,372 $15,000 Not Implemented
BD0475 # 02 Y:2016 02 2016 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION $6,954 $18,000 Not Implemented
BD0475 # 03 Y:2016 03 2016 RECOVER WASTE HEAT FROM EQUIPMENT $7,287 $9,000 Not Implemented
BD0475 # 04 Y:2016 04 2016 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,266 $4,390 Implemented
BD0475 # 05 Y:2016 05 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,317 $600 Implemented
BD0475 # 06 Y:2016 06 2016 INSTALL OCCUPANCY SENSORS $1,791 $900 Not Implemented
BD0475 # 07 Y:2016 07 2016 USE SYNTHETIC LUBRICANT $1,663 $600 Implemented