Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,573
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0262 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,763 | $400 | Implemented |
ND0262 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,676 | $3,770 | Implemented |
ND0262 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $598 | $537 | Implemented |
ND0262 # 06 Y:1996 | 06 | 1996 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $251 | $475 | Not Implemented |
ND0261 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,345 | $400 | Implemented |
ND0261 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $204 | $200 | Not Implemented |
ND0261 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $167 | $315 | Implemented |
ND0261 # 04 Y:1996 | 04 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $207 | $100 | Not Implemented |
ND0261 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $230 | $141 | Not Implemented |
ND0261 # 06 Y:1996 | 06 | 1996 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $372 | $720 | Not Implemented |
ND0261 # 07 Y:1996 | 07 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,020 | $480 | Implemented |
ND0261 # 08 Y:1996 | 08 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,700 | $480 | Implemented |
ND0264 # 01 Y:1996 | 01 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $525 | $200 | Implemented |
ND0264 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $680 | $907 | Not Implemented |
ND0264 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $362 | $210 | Implemented |
ND0264 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $322 | $200 | Implemented |
ND0264 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,650 | $480 | Implemented |
ND0264 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $8 | $70 | Implemented |
ND0263 # 01 Y:1996 | 01 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $114 | $130 | Implemented |
ND0263 # 02 Y:1996 | 02 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $62 | $300 | Not Implemented |
ND0263 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $384 | $564 | Implemented |
ND0263 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $89 | $600 | Not Implemented |
ND0263 # 05 Y:1996 | 05 | 1996 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $182 | $0 | Not Implemented |
ND0263 # 06 Y:1996 | 06 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $134 | $1,722 | Implemented |
ND0263 # 07 Y:1996 | 07 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $409 | $698 | Implemented |