IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,520

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0661 # 01 Y:1999 01 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $20,275 $4,960 Not Implemented
GT0661 # 02 Y:1999 02 1999 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $1,938 $300 Implemented
GT0661 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,740 $750 Not Implemented
GT0661 # 04 Y:1999 04 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $457 $994 Not Implemented
GT0661 # 05 Y:1999 05 1999 FILTER AND REUSE HYDRAULIC OIL $684 $1,000 Not Implemented
GT0661 # 06 Y:1999 06 1999 REDUCE SCRAP PRODUCTION $215,560 $112,500 Implemented
GT0661 # 07 Y:1999 07 1999 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $673,610 $245,000 Implemented
HO0202 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,728 $15,851 Not Implemented
HO0202 # 02 Y:1999 02 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,525 $45 Not Implemented
HO0202 # 03 Y:1999 03 1999 USE OPTIMUM THICKNESS INSULATION $3,266 $1,190 Not Implemented
HO0202 # 04 Y:1999 04 1999 INSTALL SPECTRAL REFLECTORS / DELAMP $6,188 $2,475 Not Implemented
HO0202 # 05 Y:1999 05 1999 MOVE PRODUCT USING MECHANICAL MEANS $840 $500 Not Implemented
HO0202 # 06 Y:1999 06 1999 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $3,900 $4,000 Not Implemented
HO0202 # 07 Y:1999 07 1999 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $2,492 $350 Not Implemented
NV0127 # 01 Y:1999 01 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $704 $1,500 Implemented
NV0127 # 02 Y:1999 02 1999 INSULATE BARE EQUIPMENT $123 $222 Not Implemented
NV0127 # 03 Y:1999 03 1999 OPTIMIZE PLANT POWER FACTOR $1,216 $2,533 Not Implemented
NV0127 # 04 Y:1999 04 1999 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,768 $588 Implemented
NV0127 # 05 Y:1999 05 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $375 $64 Not Implemented
NV0127 # 06 Y:1999 06 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $704 $80 Not Implemented
NV0127 # 07 Y:1999 07 1999 INSTALL SKYLIGHTS $1,727 $3,945 Not Implemented
NV0127 # 08 Y:1999 08 1999 USE RADIANT HEATER FOR SPOT HEATING $3,636 $4,525 Implemented
NV0127 # 09 Y:1999 09 1999 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,890 $0 Not Implemented
NV0127 # 10 Y:1999 10 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $1,343 $325 Implemented
NC0164 # 01 Y:1999 01 1999 ADJUST BURNERS FOR EFFICIENT OPERATION $8,380 $700 Implemented