Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,602
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0515 # 08 Y:2006 | 08 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $6,900 | $80 | Implemented |
AM0515 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,560 | $20,750 | Not Implemented |
AM0515 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $4,440 | $1,580 | Implemented |
AM0515 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,690 | $3,800 | Not Implemented |
LL0250 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $40,871 | $5,998 | Implemented |
LL0250 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $37,521 | $5,040 | Implemented |
LL0250 # 03 Y:2006 | 03 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,864 | $474 | Not Implemented |
LL0250 # 04 Y:2006 | 04 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,081 | $60 | Not Implemented |
LL0250 # 05 Y:2006 | 05 | 2006 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,580 | $596 | Not Implemented |
LL0250 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $427 | $60 | Not Implemented |
LL0250 # 07 Y:2006 | 07 | 2006 | USE PHOTOCELL CONTROLS | $294 | $30 | Not Implemented |
AM0514 # 01 Y:2006 | 01 | 2006 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $189,400 | $50,000 | Implemented |
AM0514 # 02 Y:2006 | 02 | 2006 | USE SYNTHETIC LUBRICANT | $27,782 | $0 | Not Implemented |
AM0514 # 03 Y:2006 | 03 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,900 | $500 | Implemented |
AM0514 # 04 Y:2006 | 04 | 2006 | INSTALL OCCUPANCY SENSORS | $2,520 | $790 | Implemented |
AM0514 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,305 | $1,450 | Implemented |
AM0514 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $1,520 | $100 | Not Implemented |
TA0116 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,371 | $16,650 | Not Implemented |
TA0116 # 02 Y:2006 | 02 | 2006 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $13,000 | $0 | Not Implemented |
TA0116 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,000 | $240 | Not Implemented |
TA0116 # 04 Y:2006 | 04 | 2006 | INSTALL SYSTEM TO COLLECT SCRAP | $21,734 | $1,600 | Not Implemented |
TA0116 # 05 Y:2006 | 05 | 2006 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,820 | $0 | Not Implemented |
AM0513 # 01 Y:2006 | 01 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $103,300 | $4,900 | Implemented |
AM0513 # 02 Y:2006 | 02 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $80,500 | $76,300 | Implemented |
AM0513 # 03 Y:2006 | 03 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,300 | $37,200 | Implemented |