Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,333
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0371 # 07 Y:2000 | 07 | 2000 | INCREASE USE OF AUTOMATION | $950 | $150 | Not Implemented |
AM0371 # 08 Y:2000 | 08 | 2000 | USE SYNTHETIC LUBRICANT | $635 | $0 | Not Implemented |
AM0371 # 09 Y:2000 | 09 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $522 | $0 | Implemented |
AS0276 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,105 | $3,527 | Not Implemented |
AS0276 # 02 Y:2000 | 02 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $449 | $240 | Not Implemented |
AS0276 # 03 Y:2000 | 03 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $474 | $525 | Implemented |
AS0276 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,403 | $140 | Implemented |
AS0276 # 05 Y:2000 | 05 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $593 | $1,365 | Implemented |
AS0276 # 06 Y:2000 | 06 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $13,808 | $90 | Implemented |
AS0276 # 07 Y:2000 | 07 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $575 | $60 | Not Implemented |
AS0276 # 08 Y:2000 | 08 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $370 | $170 | Not Implemented |
AS0276 # 09 Y:2000 | 09 | 2000 | APPLY FOR INVESTMENT INCENTIVES | $1,545 | $60 | Not Implemented |
AS0276 # 10 Y:2000 | 10 | 2000 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $3,240 | $12,060 | Not Implemented |
AS0276 # 11 Y:2000 | 11 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $44,269 | $150,000 | Implemented |
NV0149 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $342 | $100 | Implemented |
NV0149 # 02 Y:2000 | 02 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $454 | $0 | Not Implemented |
NV0149 # 03 Y:2000 | 03 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $37,440 | $80,000 | Not Implemented |
NV0149 # 04 Y:2000 | 04 | 2000 | ADD ADDITIONAL PRODUCTION SHIFT | $21,840 | $0 | Not Implemented |
SF0189 # 01 Y:2000 | 01 | 2000 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $8,181 | $8,239 | Implemented |
SF0189 # 02 Y:2000 | 02 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,998 | $7,800 | Not Implemented |
SF0189 # 03 Y:2000 | 03 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $807 | $1,711 | Implemented |
SF0189 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $1,491 | $2,520 | Implemented |
SF0189 # 05 Y:2000 | 05 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $8,916 | $14,480 | Implemented |
SF0189 # 06 Y:2000 | 06 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,102 | $36,670 | Implemented |
SF0189 # 07 Y:2000 | 07 | 2000 | MINIMIZE WATER USAGE | $23,452 | $125,000 | Implemented |