Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,105
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0318 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,807 | $24,950 | Implemented |
UF0318 # 04 Y:2003 | 04 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,439 | $2,619 | Not Implemented |
UF0318 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,202 | $0 | Implemented |
UF0318 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $1,117 | $852 | Not Implemented |
UF0318 # 07 Y:2003 | 07 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $11,077 | $16,791 | Not Implemented |
UF0318 # 08 Y:2003 | 08 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,449 | $0 | Implemented |
UF0318 # 09 Y:2003 | 09 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,037 | $13,339 | Implemented |
UF0318 # 10 Y:2003 | 10 | 2003 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $2,364 | $2,358 | Not Implemented |
UF0318 # 11 Y:2003 | 11 | 2003 | MAINTAIN MACHINES TO REDUCE LEAKS | $77,760 | $14,000 | Implemented |
UF0318 # 12 Y:2003 | 12 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $12,000 | $8,200 | Implemented |
LL0154 # 01 Y:2003 | 01 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $18,488,939 | $413,700 | n/a |
AS0348 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $164 | $101 | Implemented |
AS0348 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,361 | $16,680 | Implemented |
AS0348 # 03 Y:2003 | 03 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,000 | $15,500 | Not Implemented |
AS0348 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,021 | $450 | Implemented |
AS0348 # 05 Y:2003 | 05 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $413 | $2,000 | Implemented |
AS0348 # 06 Y:2003 | 06 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $93,399 | $45,312 | Not Implemented |
LL0154 # 02 Y:2003 | 02 | 2003 | INCREASE AMOUNT OF CONDENSATE RETURNED | $11,340,034 | $773,535 | n/a |
LL0154 # 03 Y:2003 | 03 | 2003 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $6,313,507 | $750,000 | Not Implemented |
LL0154 # 04 Y:2003 | 04 | 2003 | REDUCE EXCESS STEAM BLEEDING | $504,716 | $45,360 | Not Implemented |
LL0154 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $109,742 | $60,716 | Implemented |
LL0154 # 06 Y:2003 | 06 | 2003 | USE PHOTOCELL CONTROLS | $36,675 | $4,100 | Not Implemented |
LL0154 # 07 Y:2003 | 07 | 2003 | INSULATE BARE EQUIPMENT | $11,082 | $2,865 | Not Implemented |
SU0159 # 01 Y:2003 | 01 | 2003 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $5,869 | $18,122 | Not Implemented |
SU0159 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,575 | $15,750 | Not Implemented |