Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,105
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0347 # 04 Y:2003 | 04 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $10,657 | $18,000 | Not Implemented |
AS0347 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $3,155 | $14 | Not Implemented |
AS0347 # 06 Y:2003 | 06 | 2003 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $720 | $40 | Implemented |
AS0347 # 07 Y:2003 | 07 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $27,104 | $6,400 | Not Implemented |
AS0347 # 08 Y:2003 | 08 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $64,137 | $800 | Not Implemented |
AS0347 # 09 Y:2003 | 09 | 2003 | CLEAR AND RENT EXISTING SPACE | $15,165 | $11,220 | n/a |
MS0222 # 01 Y:2003 | 01 | 2003 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $11,730 | $8,788 | Not Implemented |
MS0222 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,928 | $196 | Implemented |
MS0222 # 03 Y:2003 | 03 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $2,178 | $90 | Implemented |
MS0222 # 04 Y:2003 | 04 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $2,158 | $1,649 | Not Implemented |
MS0222 # 05 Y:2003 | 05 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,994 | $0 | Not Implemented |
MS0222 # 06 Y:2003 | 06 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,717 | $1,717 | Not Implemented |
MS0222 # 07 Y:2003 | 07 | 2003 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $1,680 | $400 | Not Implemented |
UF0317 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,161 | $11,978 | n/a |
UF0317 # 02 Y:2003 | 02 | 2003 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $4,254 | $1,640 | n/a |
UF0317 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,925 | $5,839 | n/a |
UF0317 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PLANT POWER FACTOR | $5,621 | $15,000 | n/a |
UF0317 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,795 | $7,524 | n/a |
UF0317 # 06 Y:2003 | 06 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $25,640 | $120 | n/a |
UF0317 # 07 Y:2003 | 07 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $6,065 | $10,440 | n/a |
UF0317 # 08 Y:2003 | 08 | 2003 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $48,077 | $145,000 | n/a |
WV0260 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $876 | $130 | Implemented |
WV0260 # 02 Y:2003 | 02 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,475 | $198 | Not Implemented |
WV0260 # 03 Y:2003 | 03 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $456 | $250 | Not Implemented |
WV0260 # 04 Y:2003 | 04 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $597 | $52 | Implemented |