IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,474

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0001 # 09 Y:1994 09 1994 REDUCE VENTILATION AIR $21,861 $25,000 Implemented
UM0001 # 10 Y:1994 10 1994 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $4,786 $1,700 Implemented
ME0129 # 01 Y:1994 01 1994 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $5,142 $5,400 Not Implemented
ME0129 # 02 Y:1994 02 1994 RECOVER WASTE HEAT FROM EQUIPMENT $770 $900 Not Implemented
ME0129 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $20,700 $19,600 Implemented
ME0129 # 04 Y:1994 04 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $13,522 $3,800 Not Implemented
ME0129 # 05 Y:1994 05 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $1,617 $880 Implemented
AM0209 # 01 Y:1994 01 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $17,000 $27,760 Not Implemented
AM0209 # 02 Y:1994 02 1994 ADJUST BURNERS FOR EFFICIENT OPERATION $1,890 $540 Implemented
AM0209 # 03 Y:1994 03 1994 INSTALL SKYLIGHTS $955 $1,300 Implemented
AM0209 # 04 Y:1994 04 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $437 $280 Implemented
AS0115 # 01 Y:1994 01 1994 USE SYNTHETIC LUBRICANT $547 $1,774 Implemented
AS0115 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,197 $7,621 Implemented
AS0115 # 03 Y:1994 03 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,056 $18,320 Not Implemented
AS0115 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,970 $13,000 Not Implemented
AS0115 # 05 Y:1994 05 1994 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $4,051 $7,317 Implemented
AS0115 # 06 Y:1994 06 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $30,413 $135,000 Not Implemented
GT0522 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,870 $2,600 Implemented
GT0522 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,080 $16,090 Implemented
GT0522 # 03 Y:1994 03 1994 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,400 $800 Not Implemented
GT0522 # 04 Y:1994 04 1994 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $1,600 $2,590 Not Implemented
GT0522 # 05 Y:1994 05 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $240 $650 Implemented
GT0522 # 06 Y:1994 06 1994 SHUT OFF PILOTS IN STANDBY EQUIPMENT $30 $10 Not Implemented
KU0426 # 01 Y:1994 01 1994 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $4,888 $2,500 Not Implemented
KU0426 # 02 Y:1994 02 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,222 $0 Implemented