Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,723
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0108 # 05 Y:2005 | 05 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $320 | $320 | Not Implemented |
MI0108 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $556 | $556 | Not Implemented |
UF0362 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,108 | $706 | Not Implemented |
UF0362 # 02 Y:2005 | 02 | 2005 | INSTALL OCCUPANCY SENSORS | $5,310 | $2,525 | Not Implemented |
UF0362 # 03 Y:2005 | 03 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,498 | $0 | Not Implemented |
UF0362 # 04 Y:2005 | 04 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $767 | $0 | Not Implemented |
UF0362 # 05 Y:2005 | 05 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $245 | $324 | Not Implemented |
UF0362 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,793 | $16,078 | Not Implemented |
UF0362 # 07 Y:2005 | 07 | 2005 | ADD AREA LIGHTING SWITCHES | $357 | $3,655 | Not Implemented |
UF0362 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $288 | $245 | Not Implemented |
UF0362 # 09 Y:2005 | 09 | 2005 | INSULATE BARE EQUIPMENT | $1,276 | $168 | Not Implemented |
UF0362 # 10 Y:2005 | 10 | 2005 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $8,012 | $0 | Not Implemented |
UF0362 # 11 Y:2005 | 11 | 2005 | RECYCLE FLUORESCENT LAMPS | $355 | $3,496 | Not Implemented |
MI0107 # 01 Y:2005 | 01 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,544 | $600 | Not Implemented |
MI0107 # 02 Y:2005 | 02 | 2005 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,756 | $4,360 | Not Implemented |
MI0107 # 03 Y:2005 | 03 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,525 | $100 | Implemented |
MI0107 # 04 Y:2005 | 04 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,012 | $4,012 | Implemented |
MI0107 # 05 Y:2005 | 05 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,325 | $42 | Implemented |
MI0107 # 06 Y:2005 | 06 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,128 | $0 | Implemented |
MI0106 # 01 Y:2005 | 01 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $19,885 | $760 | Implemented |
MI0106 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,649 | $12,563 | Not Implemented |
MI0106 # 03 Y:2005 | 03 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,418 | $225 | Implemented |
MI0106 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,194 | $862 | Implemented |
MI0106 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,390 | $56 | Implemented |
MI0106 # 06 Y:2005 | 06 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $834 | $600 | Not Implemented |