Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,615
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0234 # 01 Y:1998 | 01 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $38,400 | $50,000 | Implemented |
ME0234 # 02 Y:1998 | 02 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $19,979 | $12,932 | Implemented |
ME0234 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,153 | $10,580 | Implemented |
ME0234 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,482 | $4,476 | Implemented |
ME0234 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,284 | $800 | Implemented |
ME0234 # 06 Y:1998 | 06 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $975 | $500 | Implemented |
ME0234 # 07 Y:1998 | 07 | 1998 | RECOVER AND REUSE COOLING WATER | $12,512 | $12,000 | Implemented |
ME0234 # 08 Y:1998 | 08 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $150 | $0 | Not Implemented |
ME0234 # 09 Y:1998 | 09 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,887 | $3,000 | Not Implemented |
ME0234 # 10 Y:1998 | 10 | 1998 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $1,114 | $7,000 | Implemented |
ME0246 # 01 Y:1998 | 01 | 1998 | USE OPTIMUM TEMPERATURE | $8,238 | $0 | Not Implemented |
ME0246 # 02 Y:1998 | 02 | 1998 | USE OPTIMUM TEMPERATURE | $7,462 | $0 | Implemented |
ME0246 # 03 Y:1998 | 03 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,928 | $0 | Implemented |
ME0246 # 04 Y:1998 | 04 | 1998 | INSULATE BARE EQUIPMENT | $5,134 | $10,930 | Implemented |
ME0246 # 05 Y:1998 | 05 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,568 | $0 | Implemented |
ME0246 # 06 Y:1998 | 06 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $18,894 | $43,500 | Implemented |
ME0247 # 01 Y:1998 | 01 | 1998 | ADOPT IN-HOUSE MATERIAL GENERATION | $33,500 | $25,500 | Implemented |
ME0247 # 02 Y:1998 | 02 | 1998 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $4,122 | $16,460 | Implemented |
ME0247 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,100 | $600 | Implemented |
ME0247 # 04 Y:1998 | 04 | 1998 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,398 | $500 | Implemented |
ME0247 # 05 Y:1998 | 05 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,102 | $1,700 | Implemented |
ME0247 # 06 Y:1998 | 06 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $360 | $0 | Implemented |
ME0247 # 07 Y:1998 | 07 | 1998 | INCREASE USE OF AUTOMATION | $45,746 | $25,500 | Implemented |
ME0247 # 08 Y:1998 | 08 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $3,330 | $1,251 | Not Implemented |
ME0245 # 01 Y:1998 | 01 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,696 | $0 | Implemented |