Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,703
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1409 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,648 | $16,700 | Not Implemented |
UK1409 # 08 Y:2014 | 08 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $33,225 | $3,000 | Not Implemented |
UK1409 # 09 Y:2014 | 09 | 2014 | INSULATE BARE EQUIPMENT | $10,898 | $18,400 | Not Implemented |
UK1409 # 10 Y:2014 | 10 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,187 | $2,400 | Not Implemented |
UK1409 # 11 Y:2014 | 11 | 2014 | ELIMINATE/REDUCE AN OPERATION | $27,643 | $9,000 | Not Implemented |
WV0496 # 03 Y:2014 | 03 | 2014 | INSTALL OCCUPANCY SENSORS | $23,310 | $0 | Implemented |
WV0496 # 13 Y:2014 | 13 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,130 | $680 | Implemented |
WV0496 # 12 Y:2014 | 12 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $2,182 | $976 | Implemented |
WV0496 # 11 Y:2014 | 11 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,920 | $1,220 | Not Implemented |
WV0496 # 10 Y:2014 | 10 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,097 | $2,200 | Not Implemented |
WV0496 # 09 Y:2014 | 09 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,604 | $0 | Implemented |
WV0496 # 08 Y:2014 | 08 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,315 | $37,440 | Not Implemented |
WV0496 # 07 Y:2014 | 07 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $11,502 | $23,800 | Not Implemented |
WV0496 # 06 Y:2014 | 06 | 2014 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $12,669 | $1,000 | Implemented |
WV0496 # 05 Y:2014 | 05 | 2014 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $15,569 | $77,120 | Not Implemented |
WV0496 # 04 Y:2014 | 04 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $18,258 | $1,700 | Implemented |
WV0496 # 02 Y:2014 | 02 | 2014 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $35,349 | $61,000 | Not Implemented |
WV0496 # 01 Y:2014 | 01 | 2014 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $46,701 | $10,800 | Not Implemented |
NC0531 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,220 | $200 | Implemented |
NC0531 # 02 Y:2014 | 02 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $80,544 | $28,000 | Implemented |
NC0531 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $836 | $240 | Implemented |
NC0531 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $874 | $1,255 | Not Implemented |
NC0531 # 05 Y:2014 | 05 | 2014 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $625 | $100 | Implemented |
NC0531 # 06 Y:2014 | 06 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,956 | $1,935 | Not Implemented |
NC0531 # 07 Y:2014 | 07 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $2,202 | $4,256 | Implemented |