IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,703

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1409 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,648 $16,700 Not Implemented
UK1409 # 08 Y:2014 08 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $33,225 $3,000 Not Implemented
UK1409 # 09 Y:2014 09 2014 INSULATE BARE EQUIPMENT $10,898 $18,400 Not Implemented
UK1409 # 10 Y:2014 10 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,187 $2,400 Not Implemented
UK1409 # 11 Y:2014 11 2014 ELIMINATE/REDUCE AN OPERATION $27,643 $9,000 Not Implemented
WV0496 # 03 Y:2014 03 2014 INSTALL OCCUPANCY SENSORS $23,310 $0 Implemented
WV0496 # 13 Y:2014 13 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,130 $680 Implemented
WV0496 # 12 Y:2014 12 2014 DEVELOP A REPAIR/REPLACE POLICY $2,182 $976 Implemented
WV0496 # 11 Y:2014 11 2014 RECOVER WASTE HEAT FROM EQUIPMENT $2,920 $1,220 Not Implemented
WV0496 # 10 Y:2014 10 2014 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,097 $2,200 Not Implemented
WV0496 # 09 Y:2014 09 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,604 $0 Implemented
WV0496 # 08 Y:2014 08 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,315 $37,440 Not Implemented
WV0496 # 07 Y:2014 07 2014 UPGRADE CONTROLS ON COMPRESSORS $11,502 $23,800 Not Implemented
WV0496 # 06 Y:2014 06 2014 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $12,669 $1,000 Implemented
WV0496 # 05 Y:2014 05 2014 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $15,569 $77,120 Not Implemented
WV0496 # 04 Y:2014 04 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $18,258 $1,700 Implemented
WV0496 # 02 Y:2014 02 2014 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $35,349 $61,000 Not Implemented
WV0496 # 01 Y:2014 01 2014 USE DEMAND CONTROLLER OR LOAD SHEDDER $46,701 $10,800 Not Implemented
NC0531 # 01 Y:2014 01 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,220 $200 Implemented
NC0531 # 02 Y:2014 02 2014 UPGRADE CONTROLS ON COMPRESSORS $80,544 $28,000 Implemented
NC0531 # 03 Y:2014 03 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $836 $240 Implemented
NC0531 # 04 Y:2014 04 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $874 $1,255 Not Implemented
NC0531 # 05 Y:2014 05 2014 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $625 $100 Implemented
NC0531 # 06 Y:2014 06 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,956 $1,935 Not Implemented
NC0531 # 07 Y:2014 07 2014 DEVELOP A REPAIR/REPLACE POLICY $2,202 $4,256 Implemented