Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,394
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0334 # 09 Y:2004 | 09 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,200 | $10,000 | Not Implemented |
SF0277 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $38,710 | $0 | Implemented |
SF0277 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,221 | $0 | Implemented |
SF0277 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,460 | $720 | Implemented |
SF0277 # 04 Y:2004 | 04 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $954 | $240 | Not Implemented |
SF0277 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $784 | $240 | Implemented |
SF0277 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $16,226 | $5,882 | Not Implemented |
SF0277 # 07 Y:2004 | 07 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,431 | $16,011 | Not Implemented |
SF0277 # 08 Y:2004 | 08 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,600 | $13,520 | Implemented |
SF0277 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $1,907 | $3,072 | Not Implemented |
SF0277 # 10 Y:2004 | 10 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,365 | $41,948 | Not Implemented |
SF0277 # 11 Y:2004 | 11 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,871 | $29,053 | Not Implemented |
SF0277 # 12 Y:2004 | 12 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,600 | $32,344 | Not Implemented |
SF0277 # 13 Y:2004 | 13 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,568 | $18,000 | Not Implemented |
SF0277 # 14 Y:2004 | 14 | 2004 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $7,239 | $0 | Not Implemented |
SF0277 # 15 Y:2004 | 15 | 2004 | CHANGE OPERATING CONDITIONS | $5,549 | $0 | Not Implemented |
SF0277 # 16 Y:2004 | 16 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,454 | $5,667 | Not Implemented |
SF0279 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $699 | $0 | Implemented |
SF0279 # 02 Y:2004 | 02 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,368 | $11,810 | Not Implemented |
SF0279 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $1,168 | $1,200 | Not Implemented |
SF0279 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,520 | $13,375 | Implemented |
SF0279 # 05 Y:2004 | 05 | 2004 | OPTIMIZE PLANT POWER FACTOR | $1,079 | $1,376 | Not Implemented |
CO0540 # 01 Y:2004 | 01 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,340 | $8,790 | Implemented |
CO0540 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $5,600 | $18,700 | Not Implemented |
CO0540 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,710 | $200 | Implemented |