Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,474

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0183 # 11 Y:1994 11 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $78 $160 Not Implemented
SD0078 # 08 Y:1994 08 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $295 $104 Implemented
SD0078 # 09 Y:1994 09 1994 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $405 $150 Not Implemented
SD0078 # 10 Y:1994 10 1994 USE PHOTOCELL CONTROLS $247 $115 Not Implemented
SD0078 # 11 Y:1994 11 1994 INSTALL OCCUPANCY SENSORS $1,241 $800 Implemented
SF0024 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $20,615 $15,734 Implemented
SF0024 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,091 $12,697 Implemented
SF0024 # 03 Y:1994 03 1994 INSTALL OCCUPANCY SENSORS $11,565 $13,467 Implemented
SF0024 # 04 Y:1994 04 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,728 $10,400 Implemented
SF0024 # 05 Y:1994 05 1994 OPTIMIZE PLANT POWER FACTOR $3,399 $6,386 Implemented
SF0024 # 06 Y:1994 06 1994 REDESIGN PROCESS $4,700 $15,500 Implemented
SF0024 # 07 Y:1994 07 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,105 $5,500 Implemented
SF0024 # 08 Y:1994 08 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $4,300 $200 Implemented
SF0024 # 09 Y:1994 09 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,030 $0 Implemented
SF0024 # 10 Y:1994 10 1994 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $399,153 $979,000 Not Implemented
SD0078 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,072 $2,240 Implemented
SD0078 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,864 $100 Implemented
SD0078 # 03 Y:1994 03 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,891 $832 Not Implemented
SD0078 # 04 Y:1994 04 1994 INSULATE BARE EQUIPMENT $152 $153 Not Implemented
SD0078 # 05 Y:1994 05 1994 INSTALL TIMERS AND/OR THERMOSTATS $1,549 $300 Not Implemented
SD0078 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,867 $2,438 Implemented
SD0078 # 07 Y:1994 07 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $4,441 $4,196 Not Implemented
SD0077 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,079 $2,580 Implemented
SD0077 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $787 $250 Implemented
SD0077 # 03 Y:1994 03 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,856 $40 Implemented