IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,521

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0343 # 05 Y:1988 05 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $14 $25 Not Implemented
GT0369 # 01 Y:1989 01 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $184 $108 Implemented
GT0369 # 02 Y:1989 02 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $943 $580 Not Implemented
GT0369 # 03 Y:1989 03 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $498 $765 Implemented
GT0369 # 04 Y:1989 04 1989 INSULATE BARE EQUIPMENT $1,950 $2,670 Not Implemented
GT0369 # 05 Y:1989 05 1989 INSTALL SET-BACK TIMERS $165 $280 Not Implemented
GT0338 # 01 Y:1988 01 1988 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $30,000 $6,670 Implemented
GT0338 # 02 Y:1988 02 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,600 $500 Implemented
GT0338 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,620 $17,560 Not Implemented
GT0338 # 04 Y:1988 04 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $420 $1,030 Not Implemented
GT0338 # 05 Y:1988 05 1988 INSULATE BARE EQUIPMENT $800 $1,320 Implemented
GT0338 # 06 Y:1988 06 1988 REPAIR AND ELIMINATE STEAM LEAKS $5,280 $4,075 Implemented
GT0338 # 07 Y:1988 07 1988 INSULATE BARE EQUIPMENT $10,930 $8,220 Not Implemented
GT0337 # 01 Y:1988 01 1988 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $15,546 $18,000 Not Implemented
GT0337 # 02 Y:1988 02 1988 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $62,540 $136,000 Not Implemented
GT0337 # 03 Y:1988 03 1988 DISCONNECT BALLASTS $1,130 $1,450 Not Implemented
GT0337 # 04 Y:1988 04 1988 INSTALL SET-BACK TIMERS $2,420 $0 Not Implemented
GT0337 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $140 $525 Not Implemented
GT0337 # 06 Y:1988 06 1988 INSULATE BARE EQUIPMENT $126 $60 Not Implemented
GT0337 # 07 Y:1988 07 1988 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,070 $3,600 Not Implemented
GT0337 # 08 Y:1988 08 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,415 $1,068 Not Implemented
GT0337 # 09 Y:1988 09 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $439 $750 Not Implemented
GT0336 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,025 $19,500 Implemented
GT0336 # 02 Y:1988 02 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $228 $228 Not Implemented
GT0336 # 03 Y:1988 03 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,130 $0 Implemented