Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,576
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0082 # 04 Y:2004 | 04 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $1,090 | $0 | Not Implemented |
TA0082 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,970 | $0 | Not Implemented |
TA0082 # 06 Y:2004 | 06 | 2004 | REDUCE HEAT GAIN BY WINDOW TINTING | $2,820 | $7,720 | Not Implemented |
AM0472 # 01 Y:2004 | 01 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $6,580 | $590 | Implemented |
AM0472 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $6,640 | $720 | Implemented |
AM0472 # 03 Y:2004 | 03 | 2004 | USE SYNTHETIC LUBRICANT | $2,630 | $0 | Not Implemented |
AM0472 # 04 Y:2004 | 04 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $950 | $290 | Implemented |
AM0472 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,000 | $200 | Implemented |
AM0472 # 06 Y:2004 | 06 | 2004 | INSTALL SKYLIGHTS | $920 | $0 | Implemented |
AM0471 # 01 Y:2004 | 01 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $7,600 | $930 | Implemented |
AM0471 # 02 Y:2004 | 02 | 2004 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $6,640 | $4,600 | Implemented |
AM0471 # 03 Y:2004 | 03 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,020 | $270 | Implemented |
AM0471 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,450 | $400 | Implemented |
AM0471 # 05 Y:2004 | 05 | 2004 | USE SYNTHETIC LUBRICANT | $1,920 | $0 | Implemented |
AM0471 # 06 Y:2004 | 06 | 2004 | INSULATE BARE EQUIPMENT | $1,110 | $170 | Implemented |
AM0471 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $230 | $630 | Implemented |
TA0081 # 01 Y:2004 | 01 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $24,080 | $31,600 | Not Implemented |
TA0081 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $14,775 | $0 | Implemented |
TA0081 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,360 | $0 | Implemented |
TA0081 # 04 Y:2004 | 04 | 2004 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $11,120 | $2,795 | Not Implemented |
TA0081 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,390 | $40 | Implemented |
TA0081 # 06 Y:2004 | 06 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,255 | $190 | Not Implemented |
TA0081 # 07 Y:2004 | 07 | 2004 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,035 | $0 | Implemented |
TA0081 # 08 Y:2004 | 08 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,880 | $0 | Not Implemented |
TA0080 # 01 Y:2004 | 01 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $67,776 | $13,000 | Implemented |