Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,105
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0431 # 10 Y:2003 | 10 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $780 | $1,520 | Not Implemented |
AM0431 # 11 Y:2003 | 11 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $760 | $0 | Implemented |
IC0053 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,095 | $5,808 | Not Implemented |
IC0053 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $950 | $2,090 | Not Implemented |
IC0053 # 03 Y:2003 | 03 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $961 | $1,069 | Implemented |
IC0053 # 04 Y:2003 | 04 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,526 | $2,954 | Not Implemented |
IC0053 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,409 | $0 | Implemented |
IC0053 # 06 Y:2003 | 06 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $10,710 | $2,925 | Implemented |
IC0053 # 07 Y:2003 | 07 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $392 | $849 | Implemented |
IC0053 # 08 Y:2003 | 08 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,772 | $4,314 | Implemented |
IC0053 # 09 Y:2003 | 09 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $5,011 | $30,665 | Not Implemented |
IC0053 # 10 Y:2003 | 10 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,908 | $44,545 | Not Implemented |
IC0053 # 11 Y:2003 | 11 | 2003 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $8,604 | $13,918 | Not Implemented |
IC0053 # 12 Y:2003 | 12 | 2003 | ADD ADDITIONAL PRODUCTION SHIFT | $261,630 | $35,000 | Implemented |
MI0051 # 01 Y:2003 | 01 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $387 | $525 | Implemented |
MI0051 # 02 Y:2003 | 02 | 2003 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $480 | $969 | Not Implemented |
MI0051 # 03 Y:2003 | 03 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,154 | $0 | Not Implemented |
OK0656 # 01 Y:2003 | 01 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $10,706 | $5,000 | Not Implemented |
OK0656 # 02 Y:2003 | 02 | 2003 | DISCONNECT BALLASTS | $3,785 | $315 | Not Implemented |
OK0656 # 03 Y:2003 | 03 | 2003 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $56,437 | $28,000 | Not Implemented |
OK0656 # 04 Y:2003 | 04 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,663 | $1,000 | Not Implemented |
OK0656 # 05 Y:2003 | 05 | 2003 | INSTALL SET-BACK TIMERS | $5,285 | $2,340 | Not Implemented |
OK0656 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $659 | $659 | Not Implemented |
SF0253 # 01 Y:2003 | 01 | 2003 | USE PHOTOCELL CONTROLS | $715 | $120 | Not Implemented |
SF0253 # 02 Y:2003 | 02 | 2003 | USE MULTIPLE-EFFECT EVAPORATORS | $88,799 | $75,000 | Not Implemented |