Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,520

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0124 # 01 Y:1999 01 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,858 $7,243 Implemented
NV0124 # 02 Y:1999 02 1999 INSULATE BARE EQUIPMENT $1,150 $800 Not Implemented
NV0124 # 03 Y:1999 03 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $292 $135 Not Implemented
NV0124 # 04 Y:1999 04 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,617 $8,520 Not Implemented
NV0124 # 05 Y:1999 05 1999 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $308 $175 Not Implemented
NV0124 # 06 Y:1999 06 1999 UTILIZE OUTSIDE CONTRACTING $93,148 $0 Implemented
WV0160 # 01 Y:1999 01 1999 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,892 $480 Not Implemented
WV0160 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $391 $212 Not Implemented
WV0160 # 03 Y:1999 03 1999 BURN A LESS EXPENSIVE GRADE OF FUEL $2,058 $1,200 Not Implemented
WV0160 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,689 $15 Implemented
WV0160 # 05 Y:1999 05 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $142 $0 Implemented
WV0160 # 06 Y:1999 06 1999 RECOVER WASTE HEAT FROM EQUIPMENT $830 $130 Implemented
WV0160 # 07 Y:1999 07 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $333 $214 Not Implemented
WV0160 # 08 Y:1999 08 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $25,624 $16,640 Not Implemented
WV0160 # 09 Y:1999 09 1999 USE OTHER WASTE CONCENTRATION METHODS $4,680 $140 Not Implemented
WV0160 # 10 Y:1999 10 1999 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $776 $5,000 Not Implemented
WV0160 # 11 Y:1999 11 1999 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $68 $0 Not Implemented
WV0160 # 12 Y:1999 12 1999 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $180,000 $11,000 Implemented
UL0214 # 01 Y:1999 01 1999 REPAIR OR REPLACE STEAM TRAPS $12,122 $6,950 Implemented
UL0214 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,243 $119 Implemented
UL0214 # 03 Y:1999 03 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,476 $2,192 Not Implemented
UM0135 # 01 Y:1999 01 1999 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $6,898 $20,000 Implemented
UM0135 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $453 $1,250 Not Implemented
UM0135 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,690 $50 Implemented
UM0135 # 04 Y:1999 04 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,660 $2,500 Implemented