Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
601
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0290 # 07 Y:2002 | 07 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $10,780 | $5,000 | Not Implemented |
SD0290 # 08 Y:2002 | 08 | 2002 | INCREASE USE OF AUTOMATION | $58,512 | $41,000 | Implemented |
SD0290 # 09 Y:2002 | 09 | 2002 | INCREASE USE OF AUTOMATION | $124,400 | $180,000 | Not Implemented |
SD0289 # 01 Y:2002 | 01 | 2002 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $1,365,840 | $2,430,000 | Not Implemented |
SD0289 # 02 Y:2002 | 02 | 2002 | INSTALL SKYLIGHTS | $57,206 | $2,700 | Not Implemented |
SD0289 # 03 Y:2002 | 03 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $27,381 | $11,000 | Not Implemented |
SD0289 # 04 Y:2002 | 04 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,500 | $11,000 | Not Implemented |
SD0289 # 05 Y:2002 | 05 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,096 | $300 | Implemented |
SD0289 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $1,066 | $800 | Not Implemented |
SD0289 # 07 Y:2002 | 07 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $91,045 | $65,000 | Not Implemented |
SD0289 # 08 Y:2002 | 08 | 2002 | RECOVER AND REUSE WASTE MATERIAL | $13,200 | $20,000 | Not Implemented |
SD0289 # 09 Y:2002 | 09 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,600 | $1,500 | Not Implemented |
SD0289 # 10 Y:2002 | 10 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $40,040 | $0 | Not Implemented |
SD0289 # 11 Y:2002 | 11 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $33,600 | $1,600 | Not Implemented |
SD0289 # 12 Y:2002 | 12 | 2002 | PAY UTILITY BILLS ON TIME | $1,554 | $0 | Not Implemented |
LM0027 # 01 Y:2002 | 01 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $16,547 | $0 | Not Implemented |
LM0027 # 02 Y:2002 | 02 | 2002 | DISCONNECT BALLASTS | $199 | $200 | Not Implemented |
LM0027 # 03 Y:2002 | 03 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $12,600 | $1,000 | Implemented |
LM0027 # 04 Y:2002 | 04 | 2002 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $100,000 | $28,080 | Not Implemented |
LM0027 # 05 Y:2002 | 05 | 2002 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $2,362 | $520 | Not Implemented |
LM0028 # 01 Y:2002 | 01 | 2002 | INSULATE BARE EQUIPMENT | $10,685 | $980 | Implemented |
LM0028 # 02 Y:2002 | 02 | 2002 | INSULATE BARE EQUIPMENT | $4,363 | $2,200 | Not Implemented |
LM0028 # 03 Y:2002 | 03 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $49,880 | $53,000 | Not Implemented |
LM0028 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,807 | $800 | Implemented |
LM0028 # 05 Y:2002 | 05 | 2002 | INSTALL SKYLIGHTS | $5,597 | $10,400 | Not Implemented |