Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,333

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0269 # 03 Y:2000 03 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,163 $320 Not Implemented
AS0269 # 04 Y:2000 04 2000 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,071 $120 Not Implemented
AS0269 # 05 Y:2000 05 2000 $2,860 $2,920 Not Implemented
AS0269 # 06 Y:2000 06 2000 $21,000 $28,000 Not Implemented
BD0153 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,555 $13,420 Implemented
BD0153 # 02 Y:2000 02 2000 INSTALL OCCUPANCY SENSORS $3,918 $930 Implemented
BD0153 # 03 Y:2000 03 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,648 $1,125 Implemented
BD0153 # 04 Y:2000 04 2000 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $826 $0 Implemented
BD0153 # 05 Y:2000 05 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $245 $235 Not Implemented
BD0153 # 06 Y:2000 06 2000 USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE $1,494 $4,825 Not Implemented
BD0153 # 07 Y:2000 07 2000 MODIFY MATERIAL APPLICATION METHODS $1,171 $1,500 Implemented
BD0153 # 08 Y:2000 08 2000 $7,644 $7,000 Not Implemented
ME0282 # 01 Y:2000 01 2000 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $80,666 $36,000 Implemented
ME0282 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,760 $8,904 Not Implemented
ME0282 # 03 Y:2000 03 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,228 $250 Implemented
ME0282 # 04 Y:2000 04 2000 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,181 $4,360 Not Implemented
ME0282 # 05 Y:2000 05 2000 MINIMIZE WATER USAGE $12,262 $1,000 Implemented
GT0682 # 01 Y:2000 01 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $48,133 $1,000 Not Implemented
GT0682 # 02 Y:2000 02 2000 $36,150 $145,000 Not Implemented
GT0682 # 03 Y:2000 03 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $16,620 $10,500 Implemented
GT0682 # 04 Y:2000 04 2000 RECOVER WASTE HEAT FROM EQUIPMENT $12,474 $45,900 Not Implemented
GT0682 # 05 Y:2000 05 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,829 $300 Not Implemented
GT0682 # 06 Y:2000 06 2000 DISCONNECT BALLASTS $651 $1,612 Implemented
GT0682 # 07 Y:2000 07 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,239 $0 Implemented
GT0682 # 08 Y:2000 08 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,071 $42,000 Implemented