Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,474
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0507 # 09 Y:1994 | 09 | 1994 | INSULATE BARE EQUIPMENT | $421 | $481 | Not Implemented |
SD0073 # 01 Y:1994 | 01 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $348 | $20 | Implemented |
SD0073 # 02 Y:1994 | 02 | 1994 | INSULATE BARE EQUIPMENT | $593 | $334 | Implemented |
SD0073 # 03 Y:1994 | 03 | 1994 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $3,860 | $240 | Implemented |
SD0073 # 04 Y:1994 | 04 | 1994 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $147 | $75 | Implemented |
SD0073 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $305 | $175 | Implemented |
SD0073 # 06 Y:1994 | 06 | 1994 | USE POWER DURING OFF-PEAK PERIODS | $1,046 | $0 | Implemented |
CO0293 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,590 | $14,640 | Not Implemented |
CO0293 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,220 | $9,380 | Implemented |
CO0293 # 03 Y:1994 | 03 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,500 | $1,600 | Not Implemented |
CO0293 # 04 Y:1994 | 04 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,290 | $1,810 | Not Implemented |
CO0293 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,260 | $1,360 | Not Implemented |
CO0293 # 06 Y:1994 | 06 | 1994 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,220 | $1,800 | Not Implemented |
CO0293 # 07 Y:1994 | 07 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $550 | $420 | Implemented |
IA0075 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,332 | $1,285 | Implemented |
IA0075 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $554 | $1,013 | Implemented |
IA0075 # 03 Y:1994 | 03 | 1994 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,738 | $995 | Implemented |
IA0075 # 04 Y:1994 | 04 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,369 | $1,000 | Not Implemented |
IA0075 # 05 Y:1994 | 05 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $645 | $573 | Implemented |
IA0075 # 06 Y:1994 | 06 | 1994 | OPTIMIZE PLANT POWER FACTOR | $744 | $3,210 | Not Implemented |
WV0021 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $613 | $2,593 | Implemented |
WV0021 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $106 | $3,890 | Implemented |
WV0021 # 03 Y:1994 | 03 | 1994 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,191 | $490 | Not Implemented |
WV0021 # 04 Y:1994 | 04 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $340 | $560 | Not Implemented |
WV0021 # 05 Y:1994 | 05 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $215 | $280 | Not Implemented |