Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
178
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0227 # 11 Y:2001 | 11 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,277 | $2,690 | Not Implemented |
NC0227 # 02 Y:2001 | 02 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,815 | $30,000 | Not Implemented |
NC0227 # 09 Y:2001 | 09 | 2001 | ADJUST BURNERS FOR EFFICIENT OPERATION | $17,577 | $15,000 | Not Implemented |
NC0227 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $662 | $308 | Not Implemented |
NC0227 # 06 Y:2001 | 06 | 2001 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $200,000 | $35,000 | Not Implemented |
NC0227 # 15 Y:2001 | 15 | 2001 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $23,716 | $15,000 | Not Implemented |
NC0227 # 07 Y:2001 | 07 | 2001 | CONTROL PRESSURE ON STEAMER OPERATIONS | $7,356 | $7,500 | Implemented |
NC0227 # 10 Y:2001 | 10 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $2,636 | $4,205 | Implemented |
NC0227 # 08 Y:2001 | 08 | 2001 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,500 | $5,000 | Not Implemented |
NC0227 # 05 Y:2001 | 05 | 2001 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $30,612 | $50,000 | Not Implemented |
NC0214 # 04 Y:2001 | 04 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $44,160 | $90,000 | Not Implemented |
NC0214 # 03 Y:2001 | 03 | 2001 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $158,850 | $100,000 | Implemented |
NC0214 # 05 Y:2001 | 05 | 2001 | DEVELOP STANDARD OPERATING PROCEDURES | $3,000 | $5,000 | Not Implemented |
NC0214 # 06 Y:2001 | 06 | 2001 | DEVELOP STANDARD OPERATING PROCEDURES | $8,000 | $500 | Implemented |
NC0214 # 07 Y:2001 | 07 | 2001 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $65,115 | $86,000 | Implemented |
NC0214 # 02 Y:2001 | 02 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $82,133 | $143,940 | n/a |
NC0214 # 01 Y:2001 | 01 | 2001 | USE PHOTOCELL CONTROLS | $2,595 | $2,000 | Implemented |
NC0225 # 01 Y:2001 | 01 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $2,783 | $1,895 | Implemented |
NC0225 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,625 | $33,848 | Implemented |
NC0225 # 06 Y:2001 | 06 | 2001 | KEEP BOILER TUBES CLEAN | $3,649 | $13,000 | Implemented |
NC0225 # 03 Y:2001 | 03 | 2001 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $27,745 | $33,990 | n/a |
NC0225 # 07 Y:2001 | 07 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $8,655 | $3,500 | Implemented |
NC0225 # 05 Y:2001 | 05 | 2001 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $20,000 | $40,000 | n/a |
NC0225 # 04 Y:2001 | 04 | 2001 | ELIMINATE COMBUSTIBLE GAS IN FLUE GAS | $15,365 | $5,000 | Implemented |
NC0225 # 08 Y:2001 | 08 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,105 | $100,000 | Implemented |