Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,377
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0049 # 04 Y:1985 | 04 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $33,063 | $3,200 | Not Implemented |
MA0048 # 05 Y:1985 | 05 | 1985 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,082 | $2,095 | Not Implemented |
CO0050 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $16,221 | $2,791 | Implemented |
MA0049 # 03 Y:1985 | 03 | 1985 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $15,656 | $40,000 | Not Implemented |
CO0050 # 01 Y:1985 | 01 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,161 | $6,500 | Not Implemented |
UD0185 # 01 Y:1985 | 01 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $33,827 | $54,000 | Implemented |
UD0183 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,945 | $575 | Implemented |
MA0048 # 02 Y:1985 | 02 | 1985 | INSTALL TURBULATORS | $636 | $2,200 | Implemented |
UD0184 # 03 Y:1985 | 03 | 1985 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,968 | $0 | Implemented |
MA0049 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,081 | $87 | Not Implemented |
UD0185 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,629 | $30,202 | Implemented |
MA0050 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,600 | $55 | Implemented |
CO0050 # 05 Y:1985 | 05 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,313 | $1,600 | Implemented |
CO0045 # 06 Y:1985 | 06 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,215 | $6,411 | Implemented |
CO0046 # 03 Y:1985 | 03 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,126 | $29,000 | Not Implemented |
CO0046 # 02 Y:1985 | 02 | 1985 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $10,101 | $4,825 | Not Implemented |
CO0046 # 08 Y:1985 | 08 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,652 | $200 | Not Implemented |
CO0045 # 04 Y:1985 | 04 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $559 | $400 | Not Implemented |
CO0046 # 07 Y:1985 | 07 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $489 | $150 | Not Implemented |
AT0031 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $82,865 | $275 | Implemented |
AT0031 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $731 | $1,615 | Implemented |
AT0030 # 02 Y:1985 | 02 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,190 | $1,350 | Implemented |
AT0030 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $515 | $161 | Not Implemented |
CO0045 # 05 Y:1985 | 05 | 1985 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $440 | $300 | Implemented |
CO0046 # 06 Y:1985 | 06 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $977 | $1,000 | Not Implemented |