Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,485
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0223 # 01 Y:2019 | 01 | 2019 | INSTALL OCCUPANCY SENSORS | $210 | $24 | Not Implemented |
IC0223 # 02 Y:2019 | 02 | 2019 | INSTALL SPECTRAL REFLECTORS / DELAMP | $267 | $2,000 | Not Implemented |
IC0223 # 03 Y:2019 | 03 | 2019 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $264 | $0 | Not Implemented |
IC0223 # 04 Y:2019 | 04 | 2019 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $550 | $0 | Implemented |
UA0218 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,378 | $6,360 | Implemented |
UA0218 # 02 Y:2019 | 02 | 2019 | INSTALL OCCUPANCY SENSORS | $1,874 | $198 | Implemented |
UA0218 # 03 Y:2019 | 03 | 2019 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $27,441 | $2,000 | Not Implemented |
UA0218 # 04 Y:2019 | 04 | 2019 | OPTIMIZE PLANT POWER FACTOR | $7,816 | $6,955 | Not Implemented |
WM0143 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,945 | $12,879 | Not Implemented |
WM0143 # 02 Y:2019 | 02 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,367 | $6,400 | Not Implemented |
WM0143 # 03 Y:2019 | 03 | 2019 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,586 | $0 | Not Implemented |
WM0143 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,884 | $4,500 | Implemented |
WM0143 # 05 Y:2019 | 05 | 2019 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $3,255 | $0 | Not Implemented |
WM0143 # 06 Y:2019 | 06 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,250 | $0 | Not Implemented |
WM0143 # 07 Y:2019 | 07 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,164 | $1,500 | Not Implemented |
WM0143 # 08 Y:2019 | 08 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,815 | $2,460 | Not Implemented |
WM0143 # 09 Y:2019 | 09 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,598 | $2,000 | Not Implemented |
WM0143 # 10 Y:2019 | 10 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,438 | $928 | Not Implemented |
WM0143 # 11 Y:2019 | 11 | 2019 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,240 | $748 | Not Implemented |
WM0143 # 12 Y:2019 | 12 | 2019 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $979 | $0 | Not Implemented |
NC0637 # 01 Y:2019 | 01 | 2019 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $23,778 | $10,000 | Not Implemented |
NC0637 # 02 Y:2019 | 02 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,505 | $30,000 | Not Implemented |
NC0637 # 03 Y:2019 | 03 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $20,241 | $210,000 | Not Implemented |
NC0637 # 04 Y:2019 | 04 | 2019 | OPTIMIZE PLANT POWER FACTOR | $1,499 | $12,000 | Not Implemented |
UA0217 # 01 Y:2019 | 01 | 2019 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,041 | $3,585 | Not Implemented |