Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,394
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0171 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,759 | $950 | Implemented |
SU0171 # 05 Y:2004 | 05 | 2004 | OPTIMIZE PLANT POWER FACTOR | $10,041 | $7,458 | Implemented |
SU0171 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,145 | $27,936 | Not Implemented |
AS0366 # 01 Y:2004 | 01 | 2004 | ADD ADDITIONAL PRODUCTION SHIFT | $66,315 | $18,116 | Not Implemented |
AS0366 # 02 Y:2004 | 02 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $11,700 | $18,000 | Not Implemented |
AS0366 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,140 | $60 | Implemented |
AS0366 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,660 | $7,180 | Not Implemented |
AS0366 # 05 Y:2004 | 05 | 2004 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $1,275 | $573 | Implemented |
AS0366 # 06 Y:2004 | 06 | 2004 | USE SOLAR HEAT TO HEAT WATER | $468 | $1,730 | Not Implemented |
AS0366 # 07 Y:2004 | 07 | 2004 | CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING | $468 | $1,150 | Not Implemented |
AS0366 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $353 | $1,640 | Implemented |
LL0180 # 01 Y:2004 | 01 | 2004 | INSTALL OCCUPANCY SENSORS | $5,529 | $100 | Implemented |
LL0180 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $3,304 | $2,261 | Not Implemented |
LL0180 # 03 Y:2004 | 03 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,329 | $430 | Implemented |
LL0180 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,131 | $2,120 | Implemented |
LL0180 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,933 | $15 | Not Implemented |
LL0180 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,325 | $7,520 | Implemented |
LL0180 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,160 | $195 | Implemented |
LL0180 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $374 | $180 | Implemented |
LL0180 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $200 | $140 | Implemented |
UU0057 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $792 | $100 | Implemented |
UU0057 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $829 | $20 | Not Implemented |
UU0057 # 03 Y:2004 | 03 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $279 | $129 | Not Implemented |
UU0057 # 04 Y:2004 | 04 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,240 | $6,450 | Not Implemented |
UU0057 # 05 Y:2004 | 05 | 2004 | INCREASE AMOUNT OF CONDENSATE RETURNED | $4,493 | $25,000 | Not Implemented |