Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,612
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0359 # 08 Y:1999 | 08 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $872 | $1,000 | Not Implemented |
WI0359 # 09 Y:1999 | 09 | 1999 | REDUCE VENTILATION AIR | $648 | $500 | Implemented |
WI0359 # 10 Y:1999 | 10 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $278 | $0 | Implemented |
WI0358 # 01 Y:1999 | 01 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $97,790 | $44,000 | Implemented |
WI0358 # 02 Y:1999 | 02 | 1999 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $92,705 | $0 | Not Implemented |
WI0358 # 03 Y:1999 | 03 | 1999 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $54,425 | $102,000 | Not Implemented |
WI0358 # 04 Y:1999 | 04 | 1999 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $7,803 | $13,900 | Not Implemented |
WI0358 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,466 | $200 | Not Implemented |
WI0358 # 06 Y:1999 | 06 | 1999 | INSULATE BARE EQUIPMENT | $1,096 | $3,850 | Not Implemented |
WI0358 # 07 Y:1999 | 07 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $331 | $107 | Implemented |
WI0357 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,443 | $155,500 | Not Implemented |
WI0357 # 02 Y:1999 | 02 | 1999 | USE EVAPORATION TO CONCENTRATE MATERIAL | $39,582 | $76,000 | Not Implemented |
WI0357 # 03 Y:1999 | 03 | 1999 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $25,236 | $60,000 | Not Implemented |
WI0357 # 04 Y:1999 | 04 | 1999 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $24,655 | $10,800 | Implemented |
WI0357 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,282 | $1,580 | Not Implemented |
WI0357 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $900 | $210 | Implemented |
WI0357 # 07 Y:1999 | 07 | 1999 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $2,963 | $7,000 | Not Implemented |
WI0357 # 08 Y:1999 | 08 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,702 | $1,000 | Not Implemented |
WI0357 # 09 Y:1999 | 09 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,780 | $0 | Not Implemented |
WI0357 # 10 Y:1999 | 10 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,131 | $4,017 | Implemented |
WI0357 # 11 Y:1999 | 11 | 1999 | INSULATE BARE EQUIPMENT | $494 | $848 | Not Implemented |
BD0141 # 01 Y:1999 | 01 | 1999 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,170 | $8,000 | Not Implemented |
BD0141 # 02 Y:1999 | 02 | 1999 | INSTALL OCCUPANCY SENSORS | $1,259 | $825 | Not Implemented |
BD0141 # 03 Y:1999 | 03 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,301 | $500 | Implemented |
BD0141 # 04 Y:1999 | 04 | 1999 | INSTALL TURBULATORS | $466 | $840 | Not Implemented |