Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,990
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0698 # 02 Y:2004 | 02 | 2004 | COMBINE UTILITY METERS | $11,340 | $0 | Not Implemented |
UD0698 # 03 Y:2004 | 03 | 2004 | DISCONNECT BALLASTS | $7,937 | $1,195 | Not Implemented |
UD0698 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,898 | $1,635 | Implemented |
UD0698 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,310 | $0 | Not Implemented |
UD0698 # 06 Y:2004 | 06 | 2004 | IMPROVE LUBRICATION PRACTICES | $1,693 | $0 | Implemented |
UD0698 # 07 Y:2004 | 07 | 2004 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $739 | $845 | Implemented |
UD0698 # 08 Y:2004 | 08 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $478 | $2,248 | Not Implemented |
UD0698 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $84 | $270 | Implemented |
UD0697 # 01 Y:2004 | 01 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $36,804 | $0 | Implemented |
UD0697 # 02 Y:2004 | 02 | 2004 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $11,330 | $0 | Implemented |
UD0697 # 03 Y:2004 | 03 | 2004 | COVER OPEN TANKS | $5,579 | $3,590 | Not Implemented |
UD0697 # 04 Y:2004 | 04 | 2004 | REDUCE FLUID FLOW RATES | $2,950 | $0 | Implemented |
UD0697 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $2,868 | $770 | Not Implemented |
UD0697 # 06 Y:2004 | 06 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,816 | $10,786 | Not Implemented |
UD0697 # 07 Y:2004 | 07 | 2004 | USE PHOTOCELL CONTROLS | $2,756 | $11,325 | Not Implemented |
UD0697 # 08 Y:2004 | 08 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,294 | $100 | Not Implemented |
UD0697 # 09 Y:2004 | 09 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,414 | $100 | Not Implemented |
UD0697 # 10 Y:2004 | 10 | 2004 | REDUCE VENTILATION AIR | $804 | $0 | Not Implemented |
UD0697 # 11 Y:2004 | 11 | 2004 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $782 | $0 | Implemented |
UD0697 # 12 Y:2004 | 12 | 2004 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $244 | $0 | Implemented |
UD0697 # 13 Y:2004 | 13 | 2004 | INSULATE BARE EQUIPMENT | $240 | $91 | Implemented |
UD0697 # 14 Y:2004 | 14 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $49 | $0 | Not Implemented |
UD0696 # 01 Y:2004 | 01 | 2004 | AUTOMATE FINISHING PROCESS | $50,850 | $28,500 | Not Implemented |
UD0696 # 02 Y:2004 | 02 | 2004 | COVER OPEN TANKS | $19,683 | $2,870 | Not Implemented |
UD0696 # 03 Y:2004 | 03 | 2004 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $11,250 | $0 | Not Implemented |