Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,055
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0229 # 04 Y:1995 | 04 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,800 | $0 | Not Implemented |
AM0229 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,760 | $570 | Implemented |
AM0229 # 06 Y:1995 | 06 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $470 | $200 | Implemented |
AS0137 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $697 | $300 | Implemented |
AS0137 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,836 | $1,706 | Not Implemented |
AS0137 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $163 | $0 | Not Implemented |
AS0137 # 04 Y:1995 | 04 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $992 | $2,275 | Not Implemented |
AS0137 # 05 Y:1995 | 05 | 1995 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,091 | $9,000 | Not Implemented |
AS0137 # 06 Y:1995 | 06 | 1995 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,608 | $0 | Implemented |
AS0137 # 07 Y:1995 | 07 | 1995 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $154 | $750 | Not Implemented |
CO0322 # 01 Y:1995 | 01 | 1995 | INSULATE BARE EQUIPMENT | $131,920 | $35,180 | Not Implemented |
CO0322 # 02 Y:1995 | 02 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,530 | $85,020 | Not Implemented |
CO0322 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,530 | $830 | Implemented |
CO0322 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $12,270 | $16,040 | Not Implemented |
CO0322 # 05 Y:1995 | 05 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,570 | $19,930 | Implemented |
CO0322 # 06 Y:1995 | 06 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,320 | $500 | Implemented |
CO0322 # 07 Y:1995 | 07 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,650 | $7,690 | Not Implemented |
OK0457 # 01 Y:1995 | 01 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,236 | $13,720 | Not Implemented |
OK0457 # 02 Y:1995 | 02 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,691 | $64 | Implemented |
OK0457 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,741 | $4,508 | Implemented |
OK0457 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $1,344 | $3,612 | Implemented |
OK0457 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,224 | $2,077 | Implemented |
OK0457 # 06 Y:1995 | 06 | 1995 | INSULATE BARE EQUIPMENT | $882 | $2,480 | Not Implemented |
OK0457 # 07 Y:1995 | 07 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $199 | $240 | Implemented |
OK0457 # 08 Y:1995 | 08 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $49 | $76 | Implemented |