Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,130
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0414 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,246 | $14,248 | Implemented |
UD0414 # 04 Y:1993 | 04 | 1993 | INSTALL SET-BACK TIMERS | $1,773 | $500 | Implemented |
UD0414 # 05 Y:1993 | 05 | 1993 | INSTALL SET-BACK TIMERS | $1,689 | $1,500 | Implemented |
UD0414 # 06 Y:1993 | 06 | 1993 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,519 | $0 | Not Implemented |
KU0412 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,619 | $53,048 | Not Implemented |
KU0412 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $122 | $480 | Implemented |
KU0412 # 03 Y:1993 | 03 | 1993 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $12,010 | $17,000 | Not Implemented |
KU0412 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,454 | $190 | Implemented |
KU0412 # 05 Y:1993 | 05 | 1993 | RECOVER AND REUSE COOLING WATER | $11,879 | $200 | Implemented |
KU0412 # 06 Y:1993 | 06 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,463 | $8,750 | Not Implemented |
KU0412 # 07 Y:1993 | 07 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,133 | $20,000 | Not Implemented |
KU0412 # 08 Y:1993 | 08 | 1993 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,964 | $6,000 | Not Implemented |
KU0412 # 09 Y:1993 | 09 | 1993 | USE SYNTHETIC LUBRICANT | $1,426 | $0 | Not Implemented |
KU0412 # 10 Y:1993 | 10 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $548 | $946 | Implemented |
MA0285 # 01 Y:1993 | 01 | 1993 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $109,286 | $73,056 | Not Implemented |
MA0285 # 02 Y:1993 | 02 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $55,888 | $14,720 | Not Implemented |
MA0285 # 03 Y:1993 | 03 | 1993 | REPLACE BOILER | $26,214 | $0 | Implemented |
MA0285 # 04 Y:1993 | 04 | 1993 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $20,398 | $47,520 | Not Implemented |
MA0285 # 05 Y:1993 | 05 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,189 | $7,537 | Not Implemented |
MA0285 # 06 Y:1993 | 06 | 1993 | RECOVER AND REUSE COOLING WATER | $4,616 | $385 | Not Implemented |
MA0285 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,120 | $7,480 | Not Implemented |
MA0285 # 08 Y:1993 | 08 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $900 | $320 | Not Implemented |
MA0287 # 01 Y:1993 | 01 | 1993 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $334,726 | $400,000 | Not Implemented |
MA0287 # 02 Y:1993 | 02 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,949 | $29,400 | Implemented |
MA0287 # 03 Y:1993 | 03 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,570 | $45,308 | Not Implemented |