Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,718
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0106 # 01 Y:1998 | 01 | 1998 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $14,857 | $7,000 | Not Implemented |
BD0106 # 02 Y:1998 | 02 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,383 | $0 | Not Implemented |
BD0106 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,941 | $3,160 | Not Implemented |
BD0106 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,022 | $800 | Not Implemented |
BD0106 # 05 Y:1998 | 05 | 1998 | INSTALL OCCUPANCY SENSORS | $967 | $650 | Not Implemented |
BD0106 # 06 Y:1998 | 06 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $85,424 | $67,500 | Not Implemented |
BD0106 # 07 Y:1998 | 07 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $10,330 | $210 | Not Implemented |
BD0106 # 08 Y:1998 | 08 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $154,560 | $23,000 | Not Implemented |
WI0313 # 01 Y:1998 | 01 | 1998 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $4,445 | $7,155 | Implemented |
WI0313 # 02 Y:1998 | 02 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,183 | $4,200 | Not Implemented |
WI0313 # 03 Y:1998 | 03 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,208 | $2,000 | Implemented |
WI0313 # 04 Y:1998 | 04 | 1998 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $1,667 | $2,000 | Implemented |
WI0313 # 05 Y:1998 | 05 | 1998 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $256 | $0 | Not Implemented |
WI0313 # 06 Y:1998 | 06 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $251 | $0 | Implemented |
WI0312 # 01 Y:1998 | 01 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $153,750 | $30,000 | Not Implemented |
WI0312 # 02 Y:1998 | 02 | 1998 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $12,702 | $42,000 | Not Implemented |
WI0312 # 03 Y:1998 | 03 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $2,744 | $7,000 | Not Implemented |
WI0312 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,170 | $0 | Implemented |
WI0312 # 05 Y:1998 | 05 | 1998 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,422 | $0 | Not Implemented |
WI0312 # 06 Y:1998 | 06 | 1998 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $1,071 | $4,000 | Not Implemented |
WI0312 # 07 Y:1998 | 07 | 1998 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $488 | $0 | Implemented |
BD0103 # 01 Y:1998 | 01 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $15,194 | $2,400 | Implemented |
BD0103 # 02 Y:1998 | 02 | 1998 | INSTALL OCCUPANCY SENSORS | $868 | $500 | Implemented |
BD0103 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $671 | $600 | Implemented |
BD0103 # 04 Y:1998 | 04 | 1998 | USE SYNTHETIC LUBRICANT | $515 | $300 | Implemented |