Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,704
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0067 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,102 | $19,430 | Not Implemented |
BD0067 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,518 | $5,540 | Not Implemented |
BD0067 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,602 | $600 | Not Implemented |
BD0067 # 05 Y:1996 | 05 | 1996 | INSTALL OCCUPANCY SENSORS | $771 | $600 | Not Implemented |
BD0067 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $634 | $1,527 | Not Implemented |
BD0067 # 07 Y:1996 | 07 | 1996 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $8,635 | $7,000 | Not Implemented |
BD0067 # 08 Y:1996 | 08 | 1996 | RECOVER AND REUSE COOLING WATER | $7,768 | $18,570 | Not Implemented |
WI0277 # 01 Y:1996 | 01 | 1996 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $18,642 | $10,000 | Not Implemented |
WI0277 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $6,122 | $1,600 | Not Implemented |
WI0277 # 03 Y:1996 | 03 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,800 | $0 | Not Implemented |
WI0277 # 04 Y:1996 | 04 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,365 | $9,500 | Implemented |
WI0277 # 05 Y:1996 | 05 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,538 | $1,642 | Not Implemented |
WI0277 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,245 | $640 | Not Implemented |
WI0277 # 07 Y:1996 | 07 | 1996 | INSTALL AUTOMATIC STACK DAMPER | $1,948 | $3,000 | Not Implemented |
WI0277 # 08 Y:1996 | 08 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,453 | $500 | Implemented |
WI0277 # 09 Y:1996 | 09 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,309 | $1,849 | Not Implemented |
WI0277 # 10 Y:1996 | 10 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $248 | $700 | Not Implemented |
WI0276 # 01 Y:1996 | 01 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,740 | $15,000 | Not Implemented |
WI0276 # 02 Y:1996 | 02 | 1996 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $3,400 | $0 | Implemented |
WI0276 # 03 Y:1996 | 03 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,454 | $0 | Not Implemented |
WI0276 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,022 | $2,144 | Not Implemented |
WI0276 # 05 Y:1996 | 05 | 1996 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $2,230 | $0 | Not Implemented |
WI0276 # 06 Y:1996 | 06 | 1996 | INSULATE BARE EQUIPMENT | $1,122 | $2,310 | Not Implemented |
WI0276 # 07 Y:1996 | 07 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $318 | $1,380 | Not Implemented |
WI0276 # 08 Y:1996 | 08 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $440 | $500 | Implemented |