Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,602
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0297 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,880 | $300 | Implemented |
AM0297 # 07 Y:1997 | 07 | 1997 | MOVE PRODUCT USING MECHANICAL MEANS | $770 | $1,460 | Not Implemented |
AM0297 # 08 Y:1997 | 08 | 1997 | PAY UTILITY BILLS ON TIME | $510 | $0 | Implemented |
AM0297 # 09 Y:1997 | 09 | 1997 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $260 | $0 | Not Implemented |
AM0296 # 01 Y:1997 | 01 | 1997 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $9,900 | $46,000 | Not Implemented |
AM0296 # 02 Y:1997 | 02 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,900 | $990 | Not Implemented |
AM0296 # 03 Y:1997 | 03 | 1997 | OPTIMIZE PLANT POWER FACTOR | $4,100 | $10,100 | Implemented |
AM0296 # 04 Y:1997 | 04 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,520 | $0 | Not Implemented |
AM0296 # 05 Y:1997 | 05 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $780 | $80 | Implemented |
AM0296 # 06 Y:1997 | 06 | 1997 | USE SYNTHETIC LUBRICANT | $720 | $0 | Implemented |
AM0296 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $350 | $0 | Implemented |
AM0296 # 08 Y:1997 | 08 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $280 | $100 | Implemented |
AM0296 # 09 Y:1997 | 09 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $480 | $0 | Implemented |
AM0296 # 10 Y:1997 | 10 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $158 | $505 | Implemented |
AM0294 # 01 Y:1997 | 01 | 1997 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,800 | $3,900 | Not Implemented |
AM0294 # 02 Y:1997 | 02 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $4,570 | $0 | Not Implemented |
AM0294 # 03 Y:1997 | 03 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,320 | $1,090 | Not Implemented |
AM0294 # 04 Y:1997 | 04 | 1997 | OPTIMIZE PLANT POWER FACTOR | $2,730 | $7,020 | Not Implemented |
AM0294 # 05 Y:1997 | 05 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,770 | $8,000 | Not Implemented |
AM0294 # 06 Y:1997 | 06 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $1,720 | $75 | Not Implemented |
AM0294 # 07 Y:1997 | 07 | 1997 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,500 | $0 | Not Implemented |
AM0294 # 08 Y:1997 | 08 | 1997 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $480 | $110 | Implemented |
AM0295 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,500 | $2,500 | Implemented |
AM0295 # 02 Y:1997 | 02 | 1997 | USE TEFLON LINED TANKS | $9,340 | $110 | Not Implemented |
AM0295 # 03 Y:1997 | 03 | 1997 | OPTIMIZE PLANT POWER FACTOR | $10,800 | $17,500 | Not Implemented |