Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,520
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0448 # 02 Y:1999 | 02 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,147 | $6,075 | Not Implemented |
MA0448 # 03 Y:1999 | 03 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,455 | $80 | Implemented |
MA0448 # 04 Y:1999 | 04 | 1999 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $1,558 | $5,000 | Implemented |
MA0448 # 05 Y:1999 | 05 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $837 | $1,976 | Not Implemented |
MA0448 # 06 Y:1999 | 06 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $558 | $0 | Implemented |
MA0448 # 07 Y:1999 | 07 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $316 | $1,425 | Implemented |
MA0448 # 08 Y:1999 | 08 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $186 | $880 | Not Implemented |
IA0235 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,832 | $0 | Implemented |
IA0235 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,453 | $265 | Not Implemented |
IA0235 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,066 | $25 | Not Implemented |
IA0235 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $554 | $43 | Implemented |
IA0235 # 05 Y:1999 | 05 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,522 | $9,183 | Not Implemented |
IA0235 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,864 | $0 | Not Implemented |
IA0235 # 07 Y:1999 | 07 | 1999 | INSTALL OCCUPANCY SENSORS | $453 | $665 | Not Implemented |
IA0235 # 08 Y:1999 | 08 | 1999 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $431 | $650 | Not Implemented |
IA0235 # 09 Y:1999 | 09 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $15,177 | $11,511 | Not Implemented |
IA0235 # 10 Y:1999 | 10 | 1999 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $995 | $1,046 | Implemented |
IA0235 # 11 Y:1999 | 11 | 1999 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,915 | $100 | Not Implemented |
IA0235 # 12 Y:1999 | 12 | 1999 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $2,574 | $3,900 | Not Implemented |
SF0178 # 01 Y:1999 | 01 | 1999 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,431 | $0 | Implemented |
SF0178 # 02 Y:1999 | 02 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $850 | $788 | Implemented |
SF0178 # 03 Y:1999 | 03 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $442 | $600 | Implemented |
SF0178 # 04 Y:1999 | 04 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,772 | $16,500 | Not Implemented |
SF0178 # 05 Y:1999 | 05 | 1999 | USE PHOTOCELL CONTROLS | $3,556 | $14,000 | Not Implemented |
SF0178 # 06 Y:1999 | 06 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $240 | $200 | Implemented |