Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,942
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0511 # 04 Y:1997 | 04 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $27,452 | $20,000 | Implemented |
UD0511 # 05 Y:1997 | 05 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $52,379 | $35,000 | Implemented |
UD0511 # 06 Y:1997 | 06 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $56,779 | $70,000 | Implemented |
UD0511 # 07 Y:1997 | 07 | 1997 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $23,300 | $0 | Not Implemented |
UD0511 # 08 Y:1997 | 08 | 1997 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $9,802 | $0 | Implemented |
UD0511 # 09 Y:1997 | 09 | 1997 | OPTIMIZE PLANT POWER FACTOR | $6,180 | $5,000 | Not Implemented |
UD0511 # 10 Y:1997 | 10 | 1997 | RECYCLE CASTING SAND | $488,953 | $900,000 | Not Implemented |
UD0510 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PLANT POWER FACTOR | $2,926 | $5,000 | Not Implemented |
UD0510 # 02 Y:1997 | 02 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,651 | $500 | Implemented |
UD0510 # 03 Y:1997 | 03 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,314 | $1,000 | Implemented |
UD0510 # 04 Y:1997 | 04 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,641 | $0 | Not Implemented |
UD0510 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,774 | $33,595 | Not Implemented |
UD0510 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $356 | $910 | Not Implemented |
UD0509 # 01 Y:1996 | 01 | 1996 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $71,145 | $170,000 | Not Implemented |
UD0509 # 02 Y:1996 | 02 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,840 | $0 | Implemented |
UD0509 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,600 | $5,000 | Implemented |
UD0509 # 04 Y:1996 | 04 | 1996 | TREAT AND REUSE RINSE WATERS | $160,244 | $100,000 | Not Implemented |
UD0509 # 05 Y:1996 | 05 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,320 | $0 | Not Implemented |
UD0509 # 06 Y:1996 | 06 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,442 | $0 | Not Implemented |
UD0509 # 07 Y:1996 | 07 | 1996 | USE PHOTOCELL CONTROLS | $1,279 | $621 | Implemented |
UD0509 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,559 | $3,600 | Not Implemented |
UD0509 # 09 Y:1996 | 09 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $512 | $1,600 | Implemented |
UD0509 # 10 Y:1996 | 10 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,492 | $3,080 | Implemented |
UD0507 # 01 Y:1996 | 01 | 1996 | BURN A LESS EXPENSIVE GRADE OF FUEL | $5,738 | $7,500 | Not Implemented |
UD0507 # 02 Y:1996 | 02 | 1996 | USE POWER DURING OFF-PEAK PERIODS | $9,357 | $0 | Not Implemented |