IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,055

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0132 # 11 Y:1995 11 1995 CLEAN LINES WITH "PIGS" INSTEAD OF SOLVENTS / SOLUTIONS $2,738 $1,300 Not Implemented
OR0250 # 01 Y:1995 01 1995 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $16,311 $2,000 Implemented
OR0250 # 02 Y:1995 02 1995 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $5,252 $6,500 Not Implemented
OR0250 # 03 Y:1995 03 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $2,300 $600 Not Implemented
OR0250 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $228 $523 Not Implemented
OR0250 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $365 $2,985 Implemented
OR0250 # 06 Y:1995 06 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $402 $500 Not Implemented
OR0250 # 07 Y:1995 07 1995 UPGRADE CONTROLS ON COMPRESSORS $2,805 $1,830 Not Implemented
OR0249 # 01 Y:1995 01 1995 ELIMINATE/REDUCE AN OPERATION $4,425 $300 Not Implemented
OR0249 # 02 Y:1995 02 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $18,578 $4,500 Not Implemented
OR0249 # 03 Y:1995 03 1995 RECOVER WASTE HEAT FROM EQUIPMENT $12,318 $17,000 Not Implemented
OR0249 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,311 $138 Not Implemented
OR0249 # 05 Y:1995 05 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,043 $11,076 Implemented
OR0249 # 06 Y:1995 06 1995 OPTIMIZE PLANT POWER FACTOR $1,624 $5,100 Not Implemented
NC0075 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,682 $546 Implemented
NC0075 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,267 $1,710 Implemented
NC0075 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $482 $1,680 Not Implemented
NC0075 # 04 Y:1995 04 1995 USE COLD WASTE WATER TO COOL CHILLER FEED WATER $5,067 $8,000 Implemented
NC0075 # 05 Y:1995 05 1995 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $72,500 $170,000 Implemented
NC0075 # 06 Y:1995 06 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $720 $200 Implemented
MA0348 # 01 Y:1995 01 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $852 $127 Implemented
MA0348 # 02 Y:1995 02 1995 USE SYNTHETIC LUBRICANT $852 $300 Not Implemented
MA0348 # 03 Y:1995 03 1995 INSTALL OCCUPANCY SENSORS $642 $350 Not Implemented
MA0348 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,014 $1,200 Implemented
MA0348 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,011 $4,750 Implemented