Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,260

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0532 # 01 Y:2007 01 2007 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $9,500 $6,500 Implemented
AM0532 # 02 Y:2007 02 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,100 $0 Implemented
AM0532 # 03 Y:2007 03 2007 AIR CONDITION ONLY SPACE NECESSARY $1,700 $5,200 Not Implemented
AM0532 # 04 Y:2007 04 2007 INSTALL OCCUPANCY SENSORS $670 $285 Implemented
AM0532 # 05 Y:2007 05 2007 ADD AREA LIGHTING SWITCHES $320 $65 Implemented
NC0366 # 01 Y:2007 01 2007 RECOVER WASTE HEAT FROM EQUIPMENT $81,321 $400,000 Not Implemented
NC0366 # 02 Y:2007 02 2007 RECOVER WASTE HEAT FROM EQUIPMENT $61,491 $250,000 Not Implemented
NC0366 # 03 Y:2007 03 2007 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $18,013 $60,000 Not Implemented
NC0366 # 04 Y:2007 04 2007 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $71,297 $280,000 Implemented
NC0366 # 05 Y:2007 05 2007 INCREASE AMOUNT OF CONDENSATE RETURNED $12,430 $12,000 Implemented
LL0280 # 02 Y:2007 02 2007 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,024 $210 Implemented
LL0280 # 03 Y:2007 03 2007 INSULATE BARE EQUIPMENT $1,816 $558 Not Implemented
LL0280 # 04 Y:2007 04 2007 INSULATE BARE EQUIPMENT $1,780 $1,662 Not Implemented
LL0280 # 05 Y:2007 05 2007 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $475 $471 Not Implemented
LL0280 # 06 Y:2007 06 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $287 $30 Implemented
LL0280 # 07 Y:2007 07 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $111 $92 Not Implemented
UM0327 # 01 Y:2007 01 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $24,123 $9,375 Implemented
UM0327 # 02 Y:2007 02 2007 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $18,136 $9,406 Not Implemented
UM0327 # 03 Y:2007 03 2007 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $9,041 $6,735 Not Implemented
UM0327 # 04 Y:2007 04 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,637 $2,140 Not Implemented
UM0327 # 05 Y:2007 05 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,516 $1,000 Implemented
UM0327 # 06 Y:2007 06 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,955 $787 Not Implemented
UM0327 # 07 Y:2007 07 2007 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $981 $1,000 Not Implemented
UM0327 # 08 Y:2007 08 2007 COVER OPEN TANKS $561 $275 Implemented
UM0327 # 09 Y:2007 09 2007 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES $416 $780 Not Implemented