Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,602
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0159 # 06 Y:1992 | 06 | 1992 | INSULATE BARE EQUIPMENT | $244 | $440 | Implemented |
AM0157 # 01 Y:1992 | 01 | 1992 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $67,280 | $2,250 | Implemented |
AM0157 # 02 Y:1992 | 02 | 1992 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $37,400 | $53,200 | Implemented |
AM0157 # 03 Y:1992 | 03 | 1992 | INSULATE BARE EQUIPMENT | $32,285 | $96,000 | Implemented |
AM0157 # 04 Y:1992 | 04 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,410 | $0 | Implemented |
AM0157 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,180 | $630 | Implemented |
AM0157 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,470 | $4,080 | Implemented |
AM0157 # 07 Y:1992 | 07 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $960 | $0 | Implemented |
AM0158 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,797 | $7,379 | Implemented |
AM0158 # 02 Y:1992 | 02 | 1992 | INSTALL SET-BACK TIMERS | $29,200 | $19,590 | Not Implemented |
AM0158 # 03 Y:1992 | 03 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,300 | $21,640 | Not Implemented |
AM0158 # 04 Y:1992 | 04 | 1992 | OPTIMIZE PLANT POWER FACTOR | $11,800 | $32,000 | Not Implemented |
AM0158 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,200 | $960 | Implemented |
AM0158 # 06 Y:1992 | 06 | 1992 | INSULATE BARE EQUIPMENT | $4,370 | $4,050 | Not Implemented |
AM0158 # 07 Y:1992 | 07 | 1992 | REPAIR AND ELIMINATE STEAM LEAKS | $3,780 | $870 | Implemented |
AM0158 # 08 Y:1992 | 08 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,190 | $1,150 | Implemented |
AM0158 # 09 Y:1992 | 09 | 1992 | INSULATE BARE EQUIPMENT | $1,760 | $5,950 | Not Implemented |
AM0158 # 10 Y:1992 | 10 | 1992 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,600 | $170 | Implemented |
AM0158 # 11 Y:1992 | 11 | 1992 | PAY UTILITY BILLS ON TIME | $1,213 | $0 | Implemented |
AM0158 # 12 Y:1992 | 12 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $425 | $0 | Implemented |
AM0160 # 01 Y:1992 | 01 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $58,460 | $15,870 | Not Implemented |
AM0160 # 02 Y:1992 | 02 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $18,230 | $6,000 | Implemented |
AM0160 # 03 Y:1992 | 03 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,040 | $630 | Implemented |
AM0160 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,348 | $595 | Not Implemented |
AM0160 # 05 Y:1992 | 05 | 1992 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $6,360 | $0 | Implemented |