Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,333
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0174 # 02 Y:2000 | 02 | 2000 | USE OPTIMUM THICKNESS INSULATION | $5,460 | $490 | Not Implemented |
UM0174 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,906 | $1,200 | Implemented |
UM0174 # 04 Y:2000 | 04 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,038 | $500 | Implemented |
UM0174 # 05 Y:2000 | 05 | 2000 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $530 | $350 | Implemented |
UM0174 # 06 Y:2000 | 06 | 2000 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $5,080 | $25,000 | Not Implemented |
UM0174 # 07 Y:2000 | 07 | 2000 | MODIFY STARTUP/SHUTDOWN TIMES | $7,800 | $2,000 | Implemented |
WI0383 # 01 Y:2000 | 01 | 2000 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $41,291 | $72,000 | Not Implemented |
WI0383 # 02 Y:2000 | 02 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,801 | $20,000 | Not Implemented |
WI0383 # 03 Y:2000 | 03 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,946 | $22,500 | Implemented |
WI0383 # 04 Y:2000 | 04 | 2000 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,492 | $11,550 | Implemented |
WI0383 # 05 Y:2000 | 05 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,875 | $0 | Not Implemented |
WI0383 # 06 Y:2000 | 06 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,257 | $740 | Implemented |
SF0202 # 01 Y:2000 | 01 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $698 | $0 | Implemented |
SF0202 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $960 | $600 | Implemented |
SF0202 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,800 | $11,610 | Not Implemented |
SF0202 # 04 Y:2000 | 04 | 2000 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $941 | $5,000 | Not Implemented |
SF0202 # 05 Y:2000 | 05 | 2000 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $5,583 | $2,180 | Implemented |
SF0202 # 06 Y:2000 | 06 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $11,715 | $17,142 | Not Implemented |
BD0171 # 01 Y:2000 | 01 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,759 | $9,930 | Not Implemented |
BD0171 # 02 Y:2000 | 02 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,506 | $500 | Not Implemented |
BD0171 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $1,317 | $1,050 | Implemented |
BD0171 # 04 Y:2000 | 04 | 2000 | USE SYNTHETIC LUBRICANT | $1,003 | $700 | Not Implemented |
BD0171 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $767 | $600 | Implemented |
BD0171 # 06 Y:2000 | 06 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $398 | $324 | Implemented |
BD0171 # 07 Y:2000 | 07 | 2000 | COVER OPEN TANKS | $206 | $470 | Implemented |