Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9,602

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0089 # 02 Y:1990 02 1990 INSTALL SET-BACK TIMERS $1,130 $0 Implemented
AM0089 # 03 Y:1990 03 1990 IMPROVE LUBRICATION PRACTICES $561 $0 Implemented
AM0089 # 04 Y:1990 04 1990 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $524 $1,092 Not Implemented
AM0089 # 05 Y:1990 05 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $345 $0 Not Implemented
AM0089 # 06 Y:1990 06 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $308 $1,118 Implemented
AM0089 # 07 Y:1990 07 1990 TURN OFF EQUIPMENT WHEN NOT IN USE $292 $0 Implemented
AM0089 # 08 Y:1990 08 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $43 $65 Not Implemented
AM0089 # 09 Y:1990 09 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $45 $5 Not Implemented
AM0090 # 01 Y:1990 01 1990 INSULATE BARE EQUIPMENT $18,200 $4,950 Implemented
AM0090 # 02 Y:1990 02 1990 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $5,635 $15,350 Not Implemented
AM0090 # 03 Y:1990 03 1990 INSULATE BARE EQUIPMENT $625 $2,180 Implemented
AM0090 # 04 Y:1990 04 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $426 $300 Implemented
AM0090 # 05 Y:1990 05 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $420 $0 Not Implemented
AM0084 # 01 Y:1990 01 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,755 $1,000 Implemented
AM0084 # 02 Y:1990 02 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,615 $2,600 Implemented
AM0084 # 03 Y:1990 03 1990 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $2,370 $7,060 Implemented
AM0084 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $282 $606 Implemented
AM0084 # 05 Y:1990 05 1990 INSTALL SET-BACK TIMERS $270 $0 Implemented
AM0084 # 06 Y:1990 06 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $105 $0 Implemented
AM0084 # 07 Y:1990 07 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $90 $0 Implemented
AM0085 # 01 Y:1990 01 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,500 $9,570 Implemented
AM0085 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,530 $7,140 Implemented
AM0085 # 03 Y:1990 03 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,330 $960 Implemented
AM0085 # 04 Y:1990 04 1990 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $660 $0 Implemented
AM0085 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $86 $74 Implemented