Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,515
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0340 # 04 Y:2006 | 04 | 2006 | INSULATE FEEDWATER TANK | $879 | $220 | Implemented |
NC0340 # 05 Y:2006 | 05 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,698 | $7,600 | Not Implemented |
NC0340 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,146 | $1,700 | Not Implemented |
NC0340 # 07 Y:2006 | 07 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,998 | $0 | Implemented |
NC0340 # 08 Y:2006 | 08 | 2006 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $272 | $500 | Implemented |
NC0340 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $129 | $377 | Not Implemented |
NC0340 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,390 | $50 | Implemented |
NC0340 # 11 Y:2006 | 11 | 2006 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $20,000 | $20,000 | Implemented |
NC0340 # 12 Y:2006 | 12 | 2006 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $18,650 | $20,000 | Not Implemented |
NC0340 # 13 Y:2006 | 13 | 2006 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $61,400 | $25,000 | Not Implemented |
NC0344 # 01 Y:2006 | 01 | 2006 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $789,735 | $918,265 | Not Implemented |
NC0344 # 02 Y:2006 | 02 | 2006 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $460,800 | $118,971 | Implemented |
NC0344 # 03 Y:2006 | 03 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $48,795 | $35,000 | Not Implemented |
NC0344 # 04 Y:2006 | 04 | 2006 | LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION | $62,722 | $50,000 | Implemented |
NC0344 # 05 Y:2006 | 05 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $29,955 | $5,000 | Not Implemented |
NC0344 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,686 | $4,423 | Implemented |
NC0343 # 01 Y:2006 | 01 | 2006 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $137,000 | $28,000 | Not Implemented |
NC0343 # 02 Y:2006 | 02 | 2006 | REDESIGN PROCESS | $54,257 | $30,000 | Not Implemented |
NC0343 # 03 Y:2006 | 03 | 2006 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $73,265 | $260,000 | Not Implemented |
NC0343 # 04 Y:2006 | 04 | 2006 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $18,719 | $10,000 | Not Implemented |
NC0343 # 05 Y:2006 | 05 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $76,598 | $14,000 | Not Implemented |
NC0343 # 06 Y:2006 | 06 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,384 | $3,000 | Not Implemented |
NC0343 # 07 Y:2006 | 07 | 2006 | INSTALL SENSORS TO DETECT DEFECTS | $1,350,000 | $800,000 | Not Implemented |
NC0343 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $312 | $424 | Not Implemented |
NC0339 # 01 Y:2006 | 01 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $227,235 | $231,600 | Not Implemented |