Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,942
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0205 # 05 Y:1986 | 05 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,237 | $12,000 | Implemented |
UD0205 # 06 Y:1986 | 06 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,622 | $11,000 | Implemented |
UD0206 # 01 Y:1986 | 01 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,458 | $1,000 | Implemented |
UD0206 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $632 | $1,000 | Implemented |
UD0206 # 03 Y:1986 | 03 | 1986 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $11,724 | $17,000 | Implemented |
UD0202 # 01 Y:1986 | 01 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,318 | $0 | Implemented |
UD0202 # 02 Y:1986 | 02 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,487 | $7,000 | Not Implemented |
UD0202 # 03 Y:1986 | 03 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,955 | $0 | Implemented |
UD0202 # 04 Y:1986 | 04 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,636 | $791 | Implemented |
UD0202 # 05 Y:1986 | 05 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $1,504 | $80 | Implemented |
UD0203 # 01 Y:1986 | 01 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $4,191 | $15,000 | Implemented |
UD0203 # 02 Y:1986 | 02 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,221 | $1,000 | Not Implemented |
UD0203 # 03 Y:1986 | 03 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,499 | $4,200 | Implemented |
UD0203 # 04 Y:1986 | 04 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,021 | $100 | Implemented |
UD0203 # 05 Y:1986 | 05 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,888 | $2,956 | Not Implemented |
UD0205 # 01 Y:1986 | 01 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,692 | $708 | Implemented |
UD0205 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,886 | $5,000 | Implemented |
UD0205 # 03 Y:1986 | 03 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $13,480 | $52,200 | Implemented |
UD0205 # 04 Y:1986 | 04 | 1986 | INSTALL STORM WINDOWS AND DOORS | $6,617 | $6,040 | Not Implemented |
UD0199 # 01 Y:1986 | 01 | 1986 | USE MINIMUM STEAM OPERATING PRESSURE | $7,787 | $20,000 | Implemented |
UD0199 # 02 Y:1986 | 02 | 1986 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $8,568 | $2,100 | Implemented |
UD0199 # 03 Y:1986 | 03 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,090 | $600 | Implemented |
UD0199 # 04 Y:1986 | 04 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,052 | $300 | Implemented |
UD0199 # 05 Y:1986 | 05 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,004 | $0 | Not Implemented |
UD0199 # 06 Y:1986 | 06 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,044 | $0 | Implemented |