Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,433
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0160 # 08 Y:1996 | 08 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,597 | $500 | Implemented |
IA0160 # 09 Y:1996 | 09 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,059 | $1,200 | Implemented |
IA0160 # 10 Y:1996 | 10 | 1996 | MINIMIZE WATER USAGE | $790 | $750 | Implemented |
KU0467 # 01 Y:1996 | 01 | 1996 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $23,485 | $6,060 | Implemented |
KU0467 # 02 Y:1996 | 02 | 1996 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $8,070 | $2,075 | Not Implemented |
KU0467 # 03 Y:1996 | 03 | 1996 | OPTIMIZE PLANT POWER FACTOR | $4,367 | $7,650 | Implemented |
KU0467 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,980 | $236 | Implemented |
KU0467 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,938 | $556 | Implemented |
KU0467 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $1,642 | $1,500 | Implemented |
KU0467 # 07 Y:1996 | 07 | 1996 | USE SYNTHETIC LUBRICANT | $821 | $299 | Implemented |
CO0372 # 01 Y:1996 | 01 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $6,270 | $13,320 | Implemented |
CO0372 # 02 Y:1996 | 02 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,250 | $1,500 | Implemented |
CO0372 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,740 | $3,135 | Implemented |
CO0372 # 04 Y:1996 | 04 | 1996 | RECOVER AND REUSE COOLING WATER | $2,320 | $3,900 | Implemented |
CO0372 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $375 | $693 | Implemented |
CO0372 # 06 Y:1996 | 06 | 1996 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,940 | $800 | Not Implemented |
CO0372 # 07 Y:1996 | 07 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,770 | $740 | Implemented |
CO0372 # 08 Y:1996 | 08 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,360 | $1,600 | Not Implemented |
CO0372 # 09 Y:1996 | 09 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,080 | $1,780 | Implemented |
CO0372 # 10 Y:1996 | 10 | 1996 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $540 | $500 | Not Implemented |
CO0371 # 01 Y:1996 | 01 | 1996 | REVISE RAW MATERIAL SPECS | $8,100 | $1,000 | Not Implemented |
CO0371 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,840 | $7,126 | Implemented |
CO0371 # 03 Y:1996 | 03 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,720 | $1,500 | Implemented |
CO0371 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $800 | $420 | Implemented |
CO0371 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $105 | $290 | Implemented |