Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,597
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0033 # 01 Y:1988 | 01 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,218 | $49,800 | Not Implemented |
AM0033 # 02 Y:1988 | 02 | 1988 | USE OPTIMUM THICKNESS INSULATION | $4,089 | $6,575 | Not Implemented |
AM0033 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,800 | $16,400 | Not Implemented |
AM0033 # 04 Y:1988 | 04 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,454 | $810 | Implemented |
AM0033 # 05 Y:1988 | 05 | 1988 | USE OPTIMUM THICKNESS INSULATION | $2,827 | $4,000 | Not Implemented |
AM0033 # 06 Y:1988 | 06 | 1988 | INSULATE BARE EQUIPMENT | $4,496 | $11,180 | Not Implemented |
AM0033 # 07 Y:1988 | 07 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,210 | $11,080 | Not Implemented |
AM0033 # 08 Y:1988 | 08 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,107 | $0 | Not Implemented |
AM0033 # 09 Y:1988 | 09 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $460 | $144 | Not Implemented |
AM0033 # 10 Y:1988 | 10 | 1988 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $393 | $300 | Implemented |
AM0033 # 11 Y:1988 | 11 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $279 | $1,000 | Not Implemented |
AM0033 # 12 Y:1988 | 12 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $135 | $0 | Not Implemented |
AM0033 # 13 Y:1988 | 13 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50 | $152 | Not Implemented |
AM0034 # 01 Y:1988 | 01 | 1988 | INSTALL SET-BACK TIMERS | $275 | $0 | Implemented |
AM0034 # 02 Y:1988 | 02 | 1988 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $221 | $940 | Implemented |
AM0034 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27 | $23 | Implemented |
AM0034 # 04 Y:1988 | 04 | 1988 | COMBINE UTILITY METERS | $102 | $301 | Implemented |
AM0034 # 05 Y:1988 | 05 | 1988 | INSULATE BARE EQUIPMENT | $104 | $37 | Not Implemented |
AM0035 # 01 Y:1988 | 01 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,912 | $0 | Not Implemented |
AM0035 # 02 Y:1988 | 02 | 1988 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $1,311 | $6,200 | Not Implemented |
AM0035 # 03 Y:1988 | 03 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $938 | $550 | Implemented |
AM0035 # 04 Y:1988 | 04 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $696 | $85 | Implemented |
AM0035 # 05 Y:1988 | 05 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $580 | $300 | Implemented |
AM0035 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $141 | $128 | Implemented |
AM0036 # 01 Y:1988 | 01 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,240 | $127,710 | Not Implemented |