Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,317
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0475 # 16 Y:2013 | 16 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $260 | $160 | Not Implemented |
WV0474 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,986 | $15,864 | Implemented |
WV0474 # 02 Y:2013 | 02 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,866 | $21,080 | Not Implemented |
WV0474 # 03 Y:2013 | 03 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,698 | $1,000 | Implemented |
WV0474 # 04 Y:2013 | 04 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,360 | $0 | Not Implemented |
WV0474 # 05 Y:2013 | 05 | 2013 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $2,920 | $72 | Implemented |
WV0474 # 06 Y:2013 | 06 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $1,715 | $392 | Implemented |
WV0474 # 07 Y:2013 | 07 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,586 | $324 | Implemented |
WV0474 # 08 Y:2013 | 08 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $967 | $6,150 | Not Implemented |
WV0474 # 09 Y:2013 | 09 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $701 | $960 | Not Implemented |
WV0474 # 10 Y:2013 | 10 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $407 | $500 | Implemented |
WV0460 # 01 Y:2013 | 01 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,183 | $0 | Implemented |
WV0460 # 02 Y:2013 | 02 | 2013 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $14,224 | $1,000 | Implemented |
WV0460 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,833 | $27,115 | Not Implemented |
WV0460 # 04 Y:2013 | 04 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $7,221 | $553 | Implemented |
WV0460 # 05 Y:2013 | 05 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,230 | $2,734 | Not Implemented |
WV0460 # 06 Y:2013 | 06 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $2,480 | $2,088 | Not Implemented |
WV0460 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,232 | $18 | Implemented |
WV0460 # 08 Y:2013 | 08 | 2013 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,354 | $6,500 | Not Implemented |
WV0460 # 09 Y:2013 | 09 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $936 | $10,030 | Implemented |
WV0460 # 10 Y:2013 | 10 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $797 | $1,725 | Implemented |
WV0460 # 11 Y:2013 | 11 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $737 | $829 | Implemented |
WV0451 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,277 | $41,953 | Not Implemented |
WV0451 # 02 Y:2012 | 02 | 2012 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $6,271 | $1,000 | Not Implemented |
WV0451 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,062 | $5,773 | Implemented |