Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,302
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0433 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,324 | $37,346 | Not Implemented |
IA0433 # 07 Y:2008 | 07 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,364 | $4,000 | Implemented |
IA0433 # 08 Y:2008 | 08 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $587 | $142 | Implemented |
IA0433 # 09 Y:2008 | 09 | 2008 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $7,158 | $4,624 | Not Implemented |
IA0433 # 10 Y:2008 | 10 | 2008 | INSULATE BARE EQUIPMENT | $524 | $254 | Not Implemented |
IA0433 # 11 Y:2008 | 11 | 2008 | ADJUST VENTS TO MINIMIZE ENERGY USE | $3,380 | $294 | Implemented |
LE0276 # 01 Y:2008 | 01 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $144,000 | $92,000 | Implemented |
LE0276 # 02 Y:2008 | 02 | 2008 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $55,360 | $30,000 | Not Implemented |
LE0276 # 03 Y:2008 | 03 | 2008 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $38,127 | $30,600 | Not Implemented |
LE0276 # 04 Y:2008 | 04 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $18,230 | $16,000 | Implemented |
LE0276 # 05 Y:2008 | 05 | 2008 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $15,550 | $500 | Not Implemented |
LE0276 # 06 Y:2008 | 06 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $10,749 | $16,800 | Not Implemented |
LE0276 # 07 Y:2008 | 07 | 2008 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $1,838 | $3,600 | Not Implemented |
LE0276 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,479 | $53,518 | Not Implemented |
LE0276 # 09 Y:2008 | 09 | 2008 | INSTALL OCCUPANCY SENSORS | $12,548 | $600 | Not Implemented |
OK0768 # 01 Y:2008 | 01 | 2008 | USE PHOTOCELL CONTROLS | $959 | $398 | Not Implemented |
OK0768 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,022 | $4,452 | Not Implemented |
OK0768 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,704 | $17,980 | Implemented |
OK0768 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $208 | $1,615 | Not Implemented |
OK0768 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $441 | $2,703 | Not Implemented |
OK0768 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,145 | $16,980 | Not Implemented |
OK0768 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $463 | $2,027 | Not Implemented |
OK0768 # 08 Y:2008 | 08 | 2008 | REPLACE TREATED WATER WITH WELL / SURFACE WATER | $12,550 | $152,330 | Not Implemented |
OK0768 # 09 Y:2008 | 09 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,400 | $7,484 | Not Implemented |
OK0768 # 10 Y:2008 | 10 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,626 | $749 | Not Implemented |