Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,152
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0034 # 07 Y:1982 | 07 | 1982 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $695 | $600 | Not Implemented |
KU0035 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $54,065 | $36,000 | Not Implemented |
KU0035 # 02 Y:1982 | 02 | 1982 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $30,995 | $59,000 | Not Implemented |
KU0035 # 03 Y:1982 | 03 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $24,810 | $0 | Not Implemented |
KU0035 # 04 Y:1982 | 04 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,265 | $535 | Implemented |
KU0035 # 05 Y:1982 | 05 | 1982 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $8,165 | $22,000 | Implemented |
KU0036 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,455 | $1,375 | Not Implemented |
KU0036 # 02 Y:1982 | 02 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $360 | $150 | Not Implemented |
KU0036 # 03 Y:1982 | 03 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $95 | $140 | Not Implemented |
KU0036 # 04 Y:1982 | 04 | 1982 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $484 | $2,500 | Not Implemented |
KU0036 # 05 Y:1982 | 05 | 1982 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $3,212 | $10,500 | Not Implemented |
KU0037 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,133 | $5,362 | Not Implemented |
KU0037 # 02 Y:1982 | 02 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,075 | $250 | Not Implemented |
KU0037 # 03 Y:1982 | 03 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,270 | $400 | Not Implemented |
KU0037 # 04 Y:1982 | 04 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $223 | $225 | Not Implemented |
KU0037 # 05 Y:1982 | 05 | 1982 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $959 | $2,500 | Not Implemented |
TN0104 # 01 Y:1982 | 01 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $880 | $1,600 | Not Implemented |
TN0104 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $179 | $320 | Not Implemented |
TN0104 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $265 | $315 | Not Implemented |
TN0116 # 01 Y:1982 | 01 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,760 | $500 | Not Implemented |
TN0116 # 02 Y:1982 | 02 | 1982 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,377 | $0 | Not Implemented |
TN0116 # 03 Y:1982 | 03 | 1982 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $312 | $0 | Not Implemented |
TN0118 # 01 Y:1982 | 01 | 1982 | COVER OPEN TANKS | $1,586 | $120 | Implemented |
TN0118 # 02 Y:1982 | 02 | 1982 | INSULATE BARE EQUIPMENT | $309 | $630 | Implemented |
TN0118 # 03 Y:1982 | 03 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,880 | $400 | Implemented |