Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
104,815
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0336 # 05 Y:1999 | 05 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,244 | $6,000 | Not Implemented |
WI0336 # 06 Y:1999 | 06 | 1999 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $5,640 | $11,500 | Not Implemented |
WI0336 # 07 Y:1999 | 07 | 1999 | TREAT AND REUSE RINSE WATERS | $4,813 | $1,600 | Not Implemented |
WI0336 # 08 Y:1999 | 08 | 1999 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $2,805 | $8,400 | Not Implemented |
WI0336 # 09 Y:1999 | 09 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $576 | $740 | Not Implemented |
WI0339 # 01 Y:1999 | 01 | 1999 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $3,909 | $0 | Not Implemented |
WI0339 # 02 Y:1999 | 02 | 1999 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $245 | $300 | Implemented |
WI0339 # 03 Y:1999 | 03 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,824 | $1,000 | Implemented |
WI0339 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $1,826 | $2,400 | Not Implemented |
WI0339 # 05 Y:1999 | 05 | 1999 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $2,534 | $4,000 | Not Implemented |
WI0339 # 06 Y:1999 | 06 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,865 | $2,000 | Implemented |
WI0339 # 07 Y:1999 | 07 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $826 | $2,600 | Not Implemented |
WI0339 # 08 Y:1999 | 08 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $439 | $0 | Not Implemented |
UM0133 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,000 | $2,000 | Implemented |
UM0133 # 02 Y:1999 | 02 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $35,000 | $43,000 | Implemented |
UM0133 # 03 Y:1999 | 03 | 1999 | MINIMIZE WATER USAGE | $35,600 | $5,500 | Implemented |
UM0133 # 04 Y:1999 | 04 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $21,232 | $14,700 | Implemented |
UM0133 # 05 Y:1999 | 05 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $259,748 | $13,300 | Implemented |
UM0133 # 06 Y:1999 | 06 | 1999 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $307,747 | $800,000 | n/a |
UM0133 # 07 Y:1999 | 07 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $25,360 | $15,700 | Not Implemented |
NC0157 # 01 Y:1999 | 01 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,968 | $1,500 | Not Implemented |
NC0157 # 02 Y:1999 | 02 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,307 | $240 | Not Implemented |
NC0157 # 03 Y:1999 | 03 | 1999 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $6,654 | $2,000 | Not Implemented |
NC0157 # 04 Y:1999 | 04 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $98,761 | $465,000 | Not Implemented |
NC0157 # 05 Y:1999 | 05 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $17,776 | $20,000 | Not Implemented |