Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,105
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0452 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,926 | $8,580 | Not Implemented |
WI0452 # 08 Y:2003 | 08 | 2003 | USE OPTIMUM THICKNESS INSULATION | $1,592 | $687 | Not Implemented |
BD0243 # 01 Y:2003 | 01 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,372 | $2,000 | Not Implemented |
BD0243 # 02 Y:2003 | 02 | 2003 | INSTALL OCCUPANCY SENSORS | $13,962 | $8,250 | Implemented |
BD0243 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,415 | $1,200 | Implemented |
BD0243 # 04 Y:2003 | 04 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,730 | $40,000 | Not Implemented |
BD0243 # 05 Y:2003 | 05 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,799 | $1,965 | Implemented |
BD0243 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,406 | $1,000 | Implemented |
BD0243 # 07 Y:2003 | 07 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $2,458 | $4,000 | Not Implemented |
BD0243 # 08 Y:2003 | 08 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,277 | $2,030 | Implemented |
BD0243 # 09 Y:2003 | 09 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,840 | $0 | Implemented |
BD0243 # 10 Y:2003 | 10 | 2003 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,838 | $2,460 | Implemented |
BD0243 # 11 Y:2003 | 11 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $816 | $185 | Not Implemented |
BD0243 # 12 Y:2003 | 12 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $567 | $500 | Not Implemented |
BD0243 # 13 Y:2003 | 13 | 2003 | USE PHOTOCELL CONTROLS | $168 | $500 | Not Implemented |
BD0243 # 14 Y:2003 | 14 | 2003 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,772 | $5,500 | Not Implemented |
BD0243 # 15 Y:2003 | 15 | 2003 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,305 | $4,243 | Not Implemented |
BD0243 # 16 Y:2003 | 16 | 2003 | MODIFY WORKLOAD | $186,751 | $10,000 | Not Implemented |
BD0243 # 17 Y:2003 | 17 | 2003 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $49,200 | $1,000 | Implemented |
BD0243 # 18 Y:2003 | 18 | 2003 | PAY BILLS ON TIME TO AVOID LATE FEES | $320 | $0 | Not Implemented |
CO0530 # 01 Y:2003 | 01 | 2003 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $13,370 | $10,000 | Implemented |
CO0530 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,370 | $230 | Implemented |
CO0530 # 03 Y:2003 | 03 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $2,940 | $280 | Implemented |
CO0530 # 04 Y:2003 | 04 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,070 | $7,760 | Implemented |
CO0530 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $1,830 | $4,140 | Not Implemented |